Sealection Agribalance HY (High Yield) is a 2 part, semi-rigid, open cell, polyurethane insulation foam system that is that is engineered to expand to a 0.5 pound per cubic foot (pcf) density when combined in a 1:1 ratio and sprayed. Sealection Agribalance HY is sprayed onsite using certified contractors.
RATINGS
|
Standard
|
Rating
|
|
ASTM C 518
|
1-inch Thick – 3.90 Hr-ft2-ºF/Btu
4-inch Thick – 15.46 Hr-ft2-ºF/Btu
|
|
ASTM E970
|
0.31 W/cm2
|
|
ASTM D1621
|
1.1 psi
|
|
ASTM D1622
|
0.49 pcf
|
|
ASTM D1623
|
3.1 psi
|
|
ASTM D2126
|
-1.6%
|
|
ASTM D1929
|
Flash Ignition - 550º C (1022º F)
Spontaneous Ignition - 560º C (1040ºF)
|
|
ASTM E283
|
0.02 L/s/m2
|
|
ASTM E96
|
1" Thick - 25.78 perms
3" Thick - 13.02 perms
7" Thick - 11.87 perms
|
|
ASTM D2842
|
45.1%
|
|
NFPA 259
|
Average 12567 Btu/lb
|
|
ASTM C1338
|
Resistance to fungal growth
|
|
ASTM E84
|
Flame Spread Index ≤ 25
Smoke Developed Index ≤ 450
|