The fire resistant flush-mounted corner guard system consists of a flexible insulative mat material, a steel cover angle, an extruded Class A polyvinyl chloride (PVC) retainer or an extruded, aluminum retainer with or without a built-in shock cushion, and a high impact extruded polyvinyl chloride (PVC) cover.
Tests
ASTM E 84
Flame Spread Index 5
Smoke Developed Index 185
ASTM E 119
Reference Listed Design Section
Design No. |
Rating |
CG 201 |
2 hour |
CG 202 |
1 hour |
CG 203 |
2 hour |
CG 204 |
1 hour |
CG 205 |
1 hour |
CG 206 |
1 hour |
CG 207 |
2 hour |
CG 208 |
2 hour |
CG 209 |
1 hour |
CG 210 |
2 hour |
Design No. |
Rating |
CG 211 |
1 hour |
CG 212 |
2 hour |
CG 213 |
1 hour |
CG 214 |
1 hour |
CG 215 |
2 hour |
CG 216 |
2 hour |
CG 217 |
2 hour |
CG 218 |
1 hour |
CG 219 |
1 hour |
CG 220 |
2 hour |