PRODUCT DESCRIPTION
Product Direct Vent Gas Fireplace
Brand Name Jotul
Description The model Jotul GF400 DV IPI direct vent gas fireplace heater is a freestanding appliance. It is equipped and operated with an (Intermittent / Pilot on Demand) ignition system. The unit front and sides contain glass panels for viewing the flame and simulated wood logs.
The model GF400 DV IPI Direct Vent Gas Room Heater is constructed of carbon steel firebox, with a cast iron outer shell. The GF400 DV IPI is a free-standing stove that uses 4-inch by 6 5/8-inch co-axial venting. It is approved for use with snorkel vent components.
Models GF400 DV IPI
Model Similarity None
Ratings 120V, 1.5A, 60 Hz, 50W (Blower)

APPLIANCE RATINGS
  NATURAL GAS PROPANE
Model GF400 DV IPI
Orifice Size (0-2000 ft) #36 #52
Orifice Size (2000-4500 ft) #37 1.55mm
Normal Input Rate (Btu/hr)(0-2000-ft) 32,000 30,000
Normal Input Rate (Btu/hr)(2000-4500-ft) 30,000 28,500
Manifold Pressure at Normal Input Rate (in.wc/kPa) 3.8/0.95 11.0/2.74
Minimum Input Rate (Btu/hr) 17,000 14,000
Manifold Pressure at Minimum Input Rate (in.wc/kPa) 1.1/0.27 2.9/0.72
Minimum Inlet Pressure (in.wc/kPa) 5.0/1.24 12.0/2.99

VENTING INFORMATION
Any combination of rise and run may be used if it is within the boundaries indicated below. The total vent length shall not exceed 35 feet. Refer to the Owner’s Manual for more details on the permissible venting configurations.
VENTING
Vent Type Coaxial vent
Vent Size 4” x 6 5/8”
Max. Vertical Length 35-feet
Min. Vertical Length 8-feet
Max. Horizontal Length 27-feet
Min. Horizontal Length 12-in
Max. Horizontal Length at Min. Vertical Length 7-feet
Min. Vertical Length at Max. Horizontal Length 8-feet
Max. Number of Elbows 2-90°
 
VENT MANUFACTURERS
DuraVent GS
American Metal Products AmeriVent
Security Chimneys International, Ltd. Secure Vent
Selkirk Metalbestos Direct Temp
Metal-Fab, Inc. Sure-Seal Direct Vent
Industrial Chimney Corp. ExcelDirect
Bernard Dalsin Mfg. Pro Form
Olympia Chimney Supply, Inc. Ventis Direct Vent

CLEARANCES TO COMBUSTIBLE CONSTRUCTION
CLEARANCES
Rear (in/mm) 2/51
Sidewall (in/mm) 3/76
Corner (in/mm) 2/51
Ceiling (in/mm) (from unit top) 32.25/819
Mantle (in/mm) (12.5” deep) 67.75/172
 
VENTING SYSTEM CLEARANCES
Top of Horizontal Vent (in/mm) 2/51
Sides and Bottom of Horizontal Vent (in/mm) 1/25
Side of Vertical Vent (in/mm) 1/25
 
MINIMUM ALCOVE DIMENSIONS
Width (in/mm) 31.75/806
Height (in/mm) (standard legs) 61/1550
Height (in/mm) (short legs) 59/1500
Depth (in/mm) 24/610
Listing Report Return to Search
Attributes
CriteriaCSA 2.17 Ed.4 (2017) (R2022)
CriteriaANSI Z21.88 / CSA 2.33 (2019) (R2024)
CSI Code10 30 00 Fireplaces and Stoves
Fuel TypePropane
Fuel TypeNatural Gas
Listing SectionVENTED GAS FIREPLACE HEATERS