EchoFirst Solar Array
Photovoltaic moduler roofing system with EchoFirst Pan System
Class A Combustible Deck
5:12 Max Slope
Component materials must be applied in the order in which they are listed below.
Deck -Plywood
(1) layer of Polystick MTS by Polyglass
Lower Extrusion
Upper Extrusion
26 Guage EchoFirst Pan
PV Module (Options Listed Below, Manufacturer / Model):
- SolarWorld: Sunmodule SW225 Mono
- AU Optronics Corp. (AUO, BenQ Solar): PM250M00250M00, PM250AC, PM240AC, PM240/245/300
- JA Solar: JAM6, JAP6
- Motech: XS60 and IM60 Series
Alternate to PV Module: Echo First Thermal Module with vents.
Alternate to PV Module: Echo First Water Based Thermal Module
Flashing: Echo Vented Ramp Flashing or non-vented
This assembly may be installed with or without optional struts.
Each system listing identifies the deck substrate as either non-combustible or combustible. Systems evaluated for combustible decks will provide the same ratings when applied over non-combustible decks. Unless otherwise noted in individual listings, combustible decks shall be sheathed with a minimum 15/32" veneer plywood or minimum 7/16" non-veneer APA rated sheathing panel (oriented strand board panels, structural particleboard panels, composite panels or wafer-board panels) or 3/4" thick solid wood sheathing boards. The component materials of each system must be applied in the order in which they are listed. All components of the system must be listed for external fire exposure by an agency acceptable to the AHJ.
Some Roof Covering Systems have been evaluated for other performance characteristics, in addition to external fire exposure. Where applicable, such additional performance characteristics are noted within the specific listing.
In all cases, manufacturer's instructions should be consulted for installation procedures and details not covered by these listings.
Listed Materials are identified by a label or marking bearing the wording, "Listed Roofing Component", a reference number or code and the WHI Certification Mark.