Panel Type (Proprietary Construction) Wood Fire Door for installation in 20 minute (without hose stream) locations in any "Category C - Standard" Frame.
LIMITATIONS
Cylindrical or Mortise Latches with minimum 1/2" Bolt Throw and 2-3/4" Backset/Surface-Mounted Vertical Rods Fire Exit Hardware/Surface-Mounted Fire Exit Hardware/Surface-Mounted Bolts/Surface-Mounted Closer/Viewer/Kickplates/Concealed or Surface Mounted Door Bottoms, Mortised Manual Flush Bolts and Auto Flush Bolts (DCI Model # 960/962).
Configuration |
Maximum Size |
Single Swing |
4'0" wide x 8'0" high
3'0" wide x 8'6" high |
Standard Pairs |
8'0" wide x 8'0" high |
Standard Pairs with Raised Laminated panels (PB core) |
7'0" wide x 8'0" high |
Evaluated to the Following:
This category includes doors evaluated without an edge-sealing system between the door and frame. It also includes doors evaluated with a sealing system incorporated (concealed or visible) into the edge of the door by the licensed manufacturer or machining distributor.
Meeting edges of pairs may require an astragal or an edge-sealing system. Please refer to individual door listings.
These doors are eligible for use in any "Category C - Standard" frame. These doors may also be installed in frames listed in "Category C - Proprietary" in the accordance with the frame manufacturer's individual listing.
All doors listed in Category A are eligible to bear the "S" (for Smoke & Draft Control assemblies) if a listed "Category H - Smoke & Draft Control Gasket" has been applied to the assembly. Please refer to Category H for individual gasket manufacturer's listings.
All doors in this category are identified by a label or marking bearing the wording, "Listed Fire Door", a time interval, a temperature rise rating, a serial number and the Warnock Hersey Certification Mark and "UBC-7-2-97/UL-10C" OR "UBC-7-2-94/UL-10B" depending on NP or PP requirements.