Swinging hollow metal, honeycomb core fire doors intended for use in 45 and 90 minute installations.
SIZES
All doors shall be 1-3/4" thick.
Single Swing - Maximum 3'6" x 7'2"
Pairs - Maximum 7'0" x 7'2"
Swinging hollow metal, honeycomb core fire doors intended for use in 45 minute, 90 minute, and 3 hour installations.
SIZES
All doors shall be 1-3/4" thick.
| Type |
Rating |
Max Size |
| Single Swing |
3 Hour |
3'4" x 8'0" |
| Single Swing |
1-1/2 Hour |
4'0" x 8'0" |
| Pairs prepared for a single point mortise lock on the active door and top and bottom flush bolts on the inactive door, with an astragal and prepared for a strike |
1-1/2 Hour |
8'0" x 8'0" |
| Pairs prepared for mortise lock type fire exit hardware device on the active door and surface mounted or concealed vertical rod fire exit hardware devices on the inactive door with an astragal |
1-1/2 Hour |
8'0" x 8'0" |
Swinging, hollow metal, steel stiffened fire doors intended for use in 45 and 90 minute installations.
SIZES
All doors shall be 1-3/4" thick.
| Type |
Hardware |
Max Size |
| Single Swing |
Single Point Latching |
4'0"x9'0" |
| Single Swing |
Mortise or Rim Type Fire Exit Hardware |
4'0"x7'0" |
| Pairs |
Single Point Latching |
8'0"x8'0" |
| Pairs |
Mortise Latch Type Fire Exit Hardware and Surface Mounted Vertical Rod Type Fire Exit Hardware |
6'0"x7'0" |
| Double Egress |
Surface Mounted or Concealed Vertical Rod Type Fire Exit Hardware |
8'0"x7'2" |
Single swinging hollow metal fire doors equipped with a louver assembly intended for use in 45 and 90 minute installations.
SIZES
Single swing only - Maximum 3'6"x7'6"
Swinging, hollow metal, steel stiffened fire doors intended for use in 45 and 90 minute installations.
SIZES
All doors shall be 1-3/4" thick
Single - 3'6"x7'6"
Pairs - 7'0"x7'6"
Swinging, hollow metal, steel stiffened fire doors intended for use in 45 and 90 minute installations.
SIZES
All doors shall be 1-3/4" thick.
Single - Maximum 4'0"x8'0"
Pairs - Maximum 8'0"x8'0"
Single 450º F Temp Rise - Maximum 4'0"x7'0"
Swinging, hollow metal, steel stiffened fire doors intended for use in 45 and 90 minute installations.
SIZES
Single swing only - Maximum 4'0"x9'0"
1-3/4" thick
Swinging, hollow metal, steel stiffened fire doors intended for use in 3 hour, 90 and 45 minute installations.
SIZES
All doors shall be 1-3/4" thick and shall not exceed
4'0"x8'0".
| Door Type |
Rating |
| Pairs |
3 h, 90 min, 45 min |
| Double Egress |
3 h, 90 min, 45 min |
| Multiple Openings |
90 min or less |
Swinging, hollow metal, steel stiffened fire doors for use in 20-minute through 3-hour applications.
| Configuration |
Maximum Size |
| Single Swing |
4’-0” wide by 10’-0” tall by 1-3/4” thick |
| Standard Pairs |
8’-0” wide by 10’-0” tall by 1-3/4” thick |
| Double Egress |
Not Allowed |
Swinging, hollow metal, steel stiffened fire doors for use in 3 hour, 90 and 45 minute installations.
SIZES
All doors shall be 1-3/4" thick
Single Swing
Pairs
Swinging, hollow metal, steel stiffened dutch fire doors intended for use in 3 hour, 90 and 45 minute installations.
SIZES
All doors shall be 1-3/4" thick.
Each door leaf of the dutch door shall be a maximum of 3'9" high by 3'6" wide for an opening measuring 7'6" high by 3'6" wide.
Swinging, hollow metal, honeycomb core fire doors intended for use in 3 hour, 90 and 45 minute locations.
SIZES
All doors shall be 1-3/4" thick
Single swing only not to exceed 3'4"x8'0"
Swinging, hollow metal, steel stiffened fire doors intended for use in 45 and 90 minute installations.
SIZES
2-1/4" thick single swing
Maximum 3'0"x7'6"
Temperature Rise:
| Rating |
Temp Rise |
| 90 Minute |
30 min - 450º F |
| 45 Minute |
30 min - 450º F |
1-3/4" thick single swing or pairs
Single - Maximum 3'9"x7'6"
Pairs - Maximum 7'6"x7'6"
Temperature Rise:
| Rating |
Temp Rise |
| 90 Minutes |
30 min - 250º F |
| 45 Minutes |
30 min - 250º F |
Swinging, hollow metal, steel stiffened fire doors intended for use in 45 and 90 minute installations.
SIZES
All doors shall be 1-3/4" thick
Pairs - Maximum 8'0"x8'0"
Swinging, hollow metal, steel stiffened fire doors intended for use in 3 hour, 45 and 90 minute installations.
SIZES
All doors shall be 1-3/4" thick.
Single swing only - Maximum 3'0"x9'0"
Temperature Rise:
| Rating |
Temp Rise |
| 180 Minute |
30 min - 450º F |
| 90 Minute |
30 min - 450º F |
| 45 Minute |
None |
Swinging, steel covered composite fire doors intended for use in 45 and 90 minute installations.
SIZES
All doors shall be 1-3/4" thick.
-
Single swing doors shall not exceed 4'0"x8'0"
-
Single swing utilizing U.S.G. Interiors, Inc. mineral or fiber board cores shall not exceed 3'6"x7'2"
-
Doors swinging in pairs shall not exceed 7'0"x7'6"
Swinging, hollow metal, steel stiffened fire doors intended for use in up to 3 hour installations.
SIZES
All doors shall be 1-3/4" thick.
Single Swing
Pairs
Swinging, hollow metal, steel stiffened fire doors intended for use in up to 3 hour installations.
SIZES
All doors shall be 1-3/4" thick.
Single Swing
DE Pairs