| Assembly No. |
MBTechnology AC-05 |
| Slope: |
Unlimted |
| Deck Type: |
Combustible Deck |
| 1. |
Optional Insulations: Minimum 1/2” thick, glass fiber, wood fiber, phenolic, perlite, or polyisocyanurate, NOTE: When EPS insulation is applied over a metal or combustible deck, a thermal barrier complying with section 2603.4.1.5 or applicable current section of the IBC is required. |
| 2. |
1- or more Plies Layflat SBS LF25, Layfast SBS TU35, Layflat SBS LF40, Layfast SBS TU43, Layflat SBS LF60, Layfast SBS TU70; mechanically fastened or fully adhered with ASTM D312 roofing asphalt, hot mopped, or ASTM D3019 cold process adhesive. |
| 3. |
Optional: 1-Ply Superflex SBS SF160PSA fully adhered with ASTM D312 roofing asphalt, hot mopped or Fastorch SBS FT160CSA , SBS FT120PSA, SBS FT120 GSA, heat fused (torch welded). |
| 4. |
1-Ply Metalflex SBS MF160WAL, Metalflex SBS MF160WAL-CoolWhite24; fully adhered with ASTM D312 roofing asphalt or torch welded. |