PRODUCT DESCRIPTION
Product |
Direct Vent Gas Fireplace Insert |
Brand Name |
Jotul |
Description |
The model Jotul GI450 DV II direct vent gas fireplace heater is designed to inserted into existing solid-fuel fireplaces. It is equipped and operated with an (Intermittent / Pilot on Demand) ignition system. The unit front and sides contain glass panels for viewing the flame and simulated wood logs. |
Models |
GI450 DV II |
Model Similarity |
None |
Ratings |
120V, 0.83A, 60 Hz (Blower) |
APPLIANCE RATINGS
|
NATURAL GAS |
PROPANE |
Model |
GI450 DV II |
Orifice Size (0-2000 ft) |
#33 |
#52 |
Orifice Size (2000-4500 ft) |
#34 |
1.55mm |
Normal Input Rate (Btu/hr)(0-2000-ft) |
33,000 |
33,000 |
Normal Input Rate (Btu/hr)(2000-4500-ft) |
31,500 |
32,000 |
Manifold Pressure at Normal Input Rate (in.wc/kPa) |
3.5/0.87 |
11.0/2.74 |
Minimum Input Rate (Btu/hr) |
12,800 |
14,000 |
Manifold Pressure at Minimum Input Rate (in.wc/kPa) |
1.6/0.39 |
5.3/1.31 |
Minimum Inlet Pressure (in.wc/kPa) |
5.0/1.24 |
12.0/2.99 |
VENTING INFORMATION
Any combination of rise and run may be used if it is within the boundaries indicated below. The total vent length shall not exceed 35 feet. Refer to the Owner’s Manual for more details on the permissible venting configurations.
VENTING |
Vent Type |
Colinear vent |
Vent Size |
3” x 3” |
Max. Vertical Length |
40-feet |
Min. Vertical Length |
10-feet |
VENT MANUFACTURERS |
DuraVent |
|
American Metal Products |
|
Metal-Fab, Inc. |
|
Industrial Chimney Corporation |
|
Selkirk-Metalbestos |
|
Security Chimneys |
|
CLEARANCES TO COMBUSTIBLE CONSTRUCTION
CLEARANCES |
Sidewall (in/mm) (from unit center) |
24.5/622 |
Hearth Protection Width (in/mm) (from fireplace opening) |
8/203 |
Hearth Protection Depth (in/mm) (unit flush) |
16/406 |
Hearth Protection Depth (in/mm) (unit raised 6”) |
12/305 |
Side Trim (in/mm) (up to 6” thick, from fireplace center) |
20.5/521 |
Top Trim (in/mm) |
41/1041 |
Mantle (in/mm) (11.5” deep) |