PRODUCT DESCRIPTION
Habersham Metal Steel Hollow Metal Windstorm Door and Frame Assemblies are windstorm resistant door and frame outswing assemblies that are configured as single swing (SC1, SC2, SC3) and pair assemblies (PC1, PC2, PC4, PC5).
WINDSTORM RATINGS
Assembly |
Maximum
Nominal Size |
Latching Hardware |
Standards /
Rating |
Single
Outswing |
SC1 |
3'-0" × 7'-0" × 1-3/4" |
Corbin Russwin CL3300 Series Cylindrical Lock |
ASTM E330-14
ASTM E1886-13a
ASTM E1886-19
ASTM E1996-17
ASTM E1996-20
TAS 203
TAS 201
TAS 202
Design Pressure:
+ 70 PSF / -70 PSF
Impact: 350 ft-lbs
|
SC2 |
3'-0" × 7'-0" × 1-3/4" |
Sargent 8200 Series Mortise Lock |
SC3 |
3'-0" × 7'-0" × 1-3/4" |
Yale 7150 FWS with Windstorm Interlocking bracket |
Pairs Outswing |
PC1 |
6'-0" × 7'-0" × 1-3/4" |
Active: Corbin Russwin CL3300 Series Cylindrical Lockset
Inactive: Yale 988Y Surface Bolts |
PC2 |
6'-0" × 7'-0" × 1-3/4" |
Active: Sargent 8200 Series Mortise
Inactive: Sargent 988 Surface Bolts |
PC4 |
6'-0" × 7'-0" × 1-3/4" |
Yale 7150 Exit device with Windstorm interlocking
bracket on both leaves
Removable Mullion: Yale M200FWS |
PC5 |
6'-0" × 7'-0" × 1-3/4" |
Active: Concealed Vertical Rod Sargent 8600 CVR Exit Devise
Inactive: Surface Mounted Vertical Rod Sargent HV8700 |
AIR INFILTRATION RATINGS*
Assemblies |
Test Standard |
Test Type |
Air Infiltration Rate |
SC1, SC2, SC3 |
ASTM E283-04 R2012 |
Air Infiltration |
0.02 cfm / Sq. Ft. |
PC1, PC2, PC4, PC5 |
ASTM E283-04 R2012 |
Air Infiltration |
0.18 cfm / Sq. Ft. |
*When installed assemblies include the required sealing gaskets.
WATER RESISTANCE RATINGS*
Assemblies |
Test Standard |
Test Type |
Test Pressure |
SC1, SC2, SC3 |
ASTM E331-00 R2009 |
Water Resistance |
5.4 PSF - Pass |
PC1, PC2, PC4, PC5 |
ASTM E331-00 R2009 |
Water Resistance |
10.5 PSF - Pass |
*When installed assemblies include the required sealing gaskets.
FLORIDA PRODUCT APPROVAL
Product |
Florida Product Approval No. |
Habersham Metal Steel Hollow Metal Windstorm Door and Frame Assemblies |
FL14347 |