Intertek Directory of Building Products

Next Door 20-45 Min Borrowed Lights & Transom/Sidelight Door Frames Company: Next Door Company

Steel Frames (Welded Up) for Borrowed Lights (fire windows) and Transom / Sidelight Door Frame assemblies for installation in masonry and drywall openings in 20 and 45 minute locations.
 
MAXIMUM RATING
 
            45 Minute Transom and/or Side Light
 
MAXIMUM SIZE
 
  45 Minute 20 Minute
Transom/Side Light 13'6" wide x 12'0" high 13'6" wide x 12'0" high
Borrowed Light (Window) 11'4" wide x 10'0" high 13'2" wide x 9'7" high

 
Maximum Glazing Sizes:
Maximum Rating: 45 Minute
Maximum Visible Area: 1296 in.²
Maximum Visible Width: 54 in.
Maximum Visible Height: 54 in.
Glazing Material: Wired Glass 
 
Note: Fire door frame assemblies rated for 60 minutes and equipped with transom lights and/or sidelights constructed of 3/16 in. thick. Firelight glazing material for installation in walls at least 4-7/8" thick are intended for use with fire doors rated 60 minutes. Only DAP33, 100% silicone or Metacaulk 990 glazing compounds may be used to install Firelite.
MINIMUM THROAT OPENING
 
Minimum throat opening allowed: 3-1/2 inches
 
Evaluated to the following:
This category includes frames not based on ANSI-A155.1/UL-63 construction Type (such as aluminum, wood, light gauge steel, composite, etc.). These listings will reference specific door types for which each frame is qualified. All frames listed in this section may be used in positive pressure assemblies per the terms and limitations of the individual listing.
All frames in this category are identified by a label or marking bearing the wording, "Listed Fire Door Frame", the Warnock Hersey Certification Mark, "UBC-7-2-97/UL-10C. Frames rated at less than 3 hours will have a time interval noted on the label/marking. See Positive Pressure Section Header for more information
Listing Report Return to Search
Attributes
CriteriaCAN4 S104 (1985)
CriteriaNFPA 252 (2008)
CriteriaUL 10(c) (2009)
CriteriaCAN / ULC S104 (2015) (R2020)
CriteriaUL 10(c) (2016) Ed. 3 (R:27 May 2021)
CriteriaNFPA 252 (2022)
CSI Code08 11 00 Metal Doors and Frames
Fire Resistance20 Min NP Fire Doorframe with Transom and/or Sidelite
Fire Resistance20 Min PP Category C Proprietary Frame
Fire Resistance45 Min PP Category C Proprietary Frame
Fire Resistance45 Min NP Fire Doorframe with Transom and/or Sidelite
Listing SectionCATEGORY C - PROPRIETARY FRAMES