Frames Transom / Side Panel Door Frames for installation in 60 to 90 minute locations.
MAXIMUM RATING:
90 Minute Transom and/or Side Panel
MAXIMUM SIZE:
|
90 Minute |
60 Minute |
45 Minute |
20 Minute |
Transom / Side Panel |
12'0" wide x 11'4" high |
12'0" wide x 11'4" high |
12'0" wide x 11'4" high |
12'0" wide x 11'4" high |
Maximum Transom Panel: 96" wide by 48" high
Maximum Side Panel: 33" wide by 40" high
TRANSOM AND SIDE PANELS TO BE CONSTRUCTED SAME AS DOORS.
MINIMUM THROAT OPENING
Minimum throat opening allowed: 3-1/2 inches
Evaluated to the following:
This category includes frames not based on ANSI-A155.1/UL-63 construction Type (such as aluminum, wood, light gauge steel, composite, etc.). These listings will reference specific door types for which each frame is qualified. All frames listed in this section may be used in positive pressure assemblies per the terms and limitations of the individual listing.
All frames in this category are identified by a label or marking bearing the wording, "Listed Fire Door Frame", the Warnock Hersey Certification Mark, "UBC-7-2-97/UL-10C. Frames rated at less than 3 hours will have a time interval noted on the label/marking. See Positive Pressure Section Header for more information