Glassprotex (GPX) with SuperLite II-XL (or SuperSecure II-XLS) Door Assembly System
Assembly Rating - Up To 90 Minutes
Rating: |
Application: |
Maximum Size of Openings: |
60 Minute |
Singles |
4' 0" wide x 9' 0" high |
Pairs |
8' 0" wide x 9' 0" high |
90 Minute |
Singles |
4' 0" wide x 9' 0" high |
Pairs |
8' 0" wide x 9' 0" high |
Glazing Markings: D-H-T-60 and D-H-T-90
*Component Bearing the Warnock Hersey Certification Mark
Limitations:
Surface Mounted Vertical Rod Fire Exit Hardware, Pivot Hinges, Offset Hinges.
SuperLite II-XL panels - 4,952 sq. in. (1 hour), 4,876 sq. in. (1-1/2 hour).
Temp Rise - 250°F for full duration, Door and frame to be installed as a unit.
Listed fire-rated open cell glazing tape is allowed for use with SuperLite II-XL or SuperSecure II-XLS Glazing such that it is approved for fire-rated durations equal to or greater than the respective SuperLite II-XL or SuperSecure II-XLS Glazing product it is used with.
Due to the thickness of the SuperLite II-XL products (including the SuperSecure II-XLS Glazing design), the vision kit and door assembly must be fire rated and listed and labeled for use with fire rated glazings which are at least of equivalent thickness to the respective SuperLite II-XL or SuperSecure II-XLS products used.
Note: This listing is in regard to fire resistance only.