Intertek Directory of Building Products

Jotul GF 300 DV and GF 300 DV MV Direct Vent Gas Fireplace Heater Company: Jøtul North America, Inc.

PRODUCT DESCRIPTION
Product Direct Vent Gas Fireplace Heater
Brand Name Jotul
Description The model Jotul GF 300 DV direct vent gas fireplace heater is a freestanding appliance.  It is equipped and operated with a piezo/standing pilot ignition system.  The unit front contains a glass panel for viewing the flame and simulated wood logs.
Models GF300DV and GF 300 DV MV
Model Similarity The models GF300DV and GF300DV MV are identical with the only difference being that the GF300DV MV uses a pilot on demand control valve that turns off the pilot burner after 7 days of uninterrupted use.
Ratings Optional blower #156000 – 120V, 1.5A, 50W, 60Hz

APPLIANCE RATINGS
  NATURAL GAS PROPANE
Model GF300DV and GF300DV MV
Orifice Size (DMS) 38 53
Normal Input Rate (Btu/hr) 26,000 26,000
Manifold Pressure at Normal Input Rate (in-wc/kPa) 3.8/0.95 11/2.75
Minimum Input Rate (Btu/hr) 14,000 14,000
Manifold Pressure at Minimum Input Rate (in-wc/kPa) 1.2/0.30 2.9/0.75
Minimum Inlet Pressure (in-wc/kPa) 5/1.25 12/3.0

VENTING INFORMATION
Any combination of rise and run may be used if it is within the boundaries indicated below. The total vent length shall not exceed 35 feet. Refer to the Owner’s Manual for more details on the permissible venting configurations.
VENTING
Vent Type Coaxial
Vent Size 4” x 6 5/8”
Max. Vertical Length 35 ft
Min. Vertical Length 8 ft
Max. Horizontal Length 27 ft
Min. Horizontal Length 1 ft
Max. Horizontal Length at Min. Vertical Length 7 ft
Min. Vertical Length at Max. Horizontal Length 8 ft
Max. Number of Elbows 4 - 45°
 
VENT MANUFACTURERS
DuraVent, Inc. Direct Vent Pro Series
American Metal Products Amerivent
Security Chimneys International Secure Vent
Selkirk Metalbestos Direct Temp
Metal-Fab Direct Vent
ICC ExcelDirect
Bernard Dalsin Pro Form
Olympia Chimney Supply Ventis Direct Vent

CLEARANCES TO COMBUSTIBLE CONSTRUCTION
CLEARANCES
Sidewall (in/mm) 3/75
Backwall (in/mm) 2/50
Min. Ceiling Height from unit top (in/mm) 35.25/895
Vent pipe to enclosure top (in/mm) 2/50
Vent pipe to enclosure sides and bottom (in/mm) 1/25
Listing Report Return to Search
Attributes
CriteriaCSA 2.17 Ed.4 (2017) (R2022)
CriteriaANSI Z21.88 / CSA 2.33 (2019) (R2024)
CSI Code10 30 00 Fireplaces and Stoves
Fuel TypePropane
Fuel TypeNatural Gas
Listing SectionVENTED GAS FIREPLACE HEATERS
Listing SectionGAS-FIRED APPLIANCES FOR USE AT HIGH ALTITUDES
Spec ID29632