PRODUCT DESCRIPTION
| Product |
Direct Vent Gas Fireplace Heater |
| Brand Name |
Jotul |
| Description |
The model Jotul GF 300 DV direct vent gas fireplace heater is a freestanding appliance. It is equipped and operated with a piezo/standing pilot ignition system. The unit front contains a glass panel for viewing the flame and simulated wood logs. |
| Models |
GF300DV and GF 300 DV MV |
| Model Similarity |
The models GF300DV and GF300DV MV are identical with the only difference being that the GF300DV MV uses a pilot on demand control valve that turns off the pilot burner after 7 days of uninterrupted use. |
| Ratings |
Optional blower #156000 – 120V, 1.5A, 50W, 60Hz |
APPLIANCE RATINGS
| |
NATURAL GAS |
PROPANE |
| Model |
GF300DV and GF300DV MV |
| Orifice Size (DMS) |
38 |
53 |
| Normal Input Rate (Btu/hr) |
26,000 |
26,000 |
| Manifold Pressure at Normal Input Rate (in-wc/kPa) |
3.8/0.95 |
11/2.75 |
| Minimum Input Rate (Btu/hr) |
14,000 |
14,000 |
| Manifold Pressure at Minimum Input Rate (in-wc/kPa) |
1.2/0.30 |
2.9/0.75 |
| Minimum Inlet Pressure (in-wc/kPa) |
5/1.25 |
12/3.0 |
VENTING INFORMATION
Any combination of rise and run may be used if it is within the boundaries indicated below. The total vent length shall not exceed 35 feet. Refer to the Owner’s Manual for more details on the permissible venting configurations.
| VENTING |
| Vent Type |
Coaxial |
| Vent Size |
4” x 6 5/8” |
| Max. Vertical Length |
35 ft |
| Min. Vertical Length |
8 ft |
| Max. Horizontal Length |
27 ft |
| Min. Horizontal Length |
1 ft |
| Max. Horizontal Length at Min. Vertical Length |
7 ft |
| Min. Vertical Length at Max. Horizontal Length |
8 ft |
| Max. Number of Elbows |
4 - 45° |
| VENT MANUFACTURERS |
| DuraVent, Inc. |
Direct Vent Pro Series |
| American Metal Products |
Amerivent |
| Security Chimneys International |
Secure Vent |
| Selkirk Metalbestos |
Direct Temp |
| Metal-Fab |
Direct Vent |
| ICC |
ExcelDirect |
| Bernard Dalsin |
Pro Form |
| Olympia Chimney Supply |
Ventis Direct Vent |
CLEARANCES TO COMBUSTIBLE CONSTRUCTION
| CLEARANCES |
| Sidewall (in/mm) |
3/75 |
| Backwall (in/mm) |
2/50 |
| Min. Ceiling Height from unit top (in/mm) |
35.25/895 |
| Vent pipe to enclosure top (in/mm) |
2/50 |
| Vent pipe to enclosure sides and bottom (in/mm) |
1/25 |