Intertek Directory of Building Products

Viega - PureFlow PEX and Viega PureFlow System Tubing Company: Viega, LLC

Viega PureFlow PEX and Viega PureFlow System are cross-linked polyethylene tubing for use in hot and cold water distribution applications. 

FLAME SPREAD RATINGS
 
Test Standard Product Tested Flame Spread Smoke Development
ASTM E84 3/8" to 2" Viega PureFlow PEX with insulation <25 <50
ASTM E84 3/8" to 1" Viega PureFlow System with insulation <25 <50
CAN/ULC-S102.2 3/8" to 2" Viega PureFlow PEX with insulation <25 <50
CAN/ULC-S102.2 3/8" to 1" Viega PureFlow System with insulation <25 <50
CAN/ULC-S102.2 3/8" to 1/2" Viega PureFlow PEX without insulation <25 <50
CAN/ULC-S102.2 3/8" to 1/2" Viega PureFlow System without insulation <25 <50
Insulated product ratings apply only when tubing is field insulated with fiberglass insulation conforming to the following: 
·         ASTM E84 Listed
·         Flame Spread Index of < 25
·         Smoke Developed Index of < 50
·         Wall thickness – minimum 1/2”
·         There shall be no exposed tubing. Tubing may contain fittings which shall also be fully encased in insulation.
 

FIRE RATINGS
Test Standard Products Covered Rating Design Number
ASTM E119
CAN/ULC-S101
UL 263
NFPA 251
UBC 7-1
3/8" to 2" Viega PureFlow PEX with insulation

3/8" to 1" Viega PureFlow System with insulation
1-Hour VL/FWDP 60-01
ASTM E119
CAN/ULC-S101
UL 263
NFPA 251
UBC 7-1
3/8" to 2" Viega PureFlow PEX with insulation

3/8" to 1" Viega PureFlow System with insulation
1-Hour VL/FWDP 60-02
ASTM E119
CAN/ULC-S101
UL 263
NFPA 251
UBC 7-1
3/8" to 2" Viega PureFlow PEX with insulation

3/8" to 1" Viega PureFlow System with insulation
2-Hour VL/FWDP 120-01
ASTM E814
CAN/ULC-S115
3/8" to 2" Viega PureFlow PEX with insulation

3/8" to 1" Viega PureFlow System with insulation
2-Hour VL/FWDP 120-02
Listing Report Return to Search
Attributes
CriteriaCAN / ULC S101 (2007)
CriteriaASTM E84 (2010)
CriteriaCAN / ULC S102.2 (2010)
CriteriaASTM E84 (2011a)
CriteriaASTM E84 (2012)
CriteriaASTM E84 (2011c)
CriteriaASTM E84 (2011b)
CriteriaCAN / ULC S115 (2011)
CriteriaASTM E814 (2011a)
CriteriaASTM E119 (2012)
CSI Code22 11 00 Facility Water Distribution
Listing SectionBUILDING MATERIALS WITH SURFACE BURNING CHARACTERISTICS
Spec ID29892
Test TypeFlame Spread
Design Documents
Public Documents
No Results