Intertek Directory of Building Products

Total Door Category D Door/Frame Assembly 45 Minute Fire Rated 8'4-3/8" x 10'0" Double Egress Steel Stiffened Configuration Company: Total Door II, Inc.

FIRE RESISTANT PRODUCTS & COMPONENTS 

 

Steel-Faced (18 or 20 gauge) (Stiffened Core Type), Swinging Flush Door for installation in 45 minute locations (see rating information below). For use in listed proprietary (3-sided) 16 gauge welded steel frames.

Limitations*: Proprietary Latches & Hinge System/Frame/Surface-Mounted or Concealed Closers/Surface-Mounted Protection Plates/Viewer/Surface-Mounted or Mortised Door Bottoms/Vision Kit (100 sq. in. Max)

 

Maximum Sizes for Compliance to UL 10c (2009), NFPA 252 (2008), and CAN/ULC S104 (2010), Maximum Rating of 45 Minutes with Hose Stream:

Configuration

Maximum Size*

Single Swing

4'2-3/16" wide x 10'0" high

Standard Pairs

8'4-3/8" wide x 10'0" high

Double Egress Pairs

8'4-3/8" wide x 10'0" high

 
*See manufacturer's installation instructions for additional information on Smoke and Draft Control, size restrictions and limitations.
 
For use in listed fire rated steel stud or wood stud drywall applications or in listed fire rated masonry wall applications.  For drywall wall applications, steel studs shall have a minimum thickness of 18 gauge, and double studs are required to be nested around the rough opening with cross bracing to the next stud at four locations to line up with the frame anchors.
Listing Report Return to Search
Attributes
CriteriaCAN4 S104 (1985)
CriteriaNFPA 252 (2008)
CriteriaUL 10(c) (2009)
CriteriaCAN / ULC S104 (2010)
CriteriaNFPA 252 (2012)
CriteriaCAN / ULC S104 (2015) (R2020)
CriteriaUL 10(c) (2016)
CSI Code08 10 00 Doors and Frames
Fire Resistance20 Min w/Hose Positive Pressure
Fire Resistance45 Min Positive Pressure
Listing SectionCATEGORY D - DOOR/FRAME ASSEMBLIES
Spec ID30046
SwingSingle Swing
SwingStandard Pairs
SwingDouble Egress
Design Documents
No Results
Public Documents
No Results