Intertek Directory of Building Products

Stilewood "C1" 20 Minute Wood Door Frame Company: 0877658 B.C. Ltd. dba Stilewood International Door & Window

PRODUCT COVERED

Wood Door Frame "C1"

 

PRODUCT DESCRIPTION

Wood Door Frame (Knock-Down) for use singly or in pairs in 20 minute with hose stream locations.  Wall construction:  Steel/wood stud drywall.  Refer to manufacturer's installation instructions for edge sealing system requirements.

 

Maximum Sizes:

Single-Swing

3'6" wide x 8'0" high

Pairs

7'0" wide x 8'0" high

 

Minimum Wall Thickness:  3-3/4 in.

 

LIMITATIONS

Cylindrical or Mortise Latches, Mortise Manual or Automatic Flush Bolts, Mortise Automatic Door Bottom.

 

EVALUATED TO THE FOLLOWING

 

This category includes frames not based on ANSI-A155.1/UL-63 construction Type (such as aluminum, wood, light gauge steel, composite, etc.).  These listings will reference specific door types for which each frame is qualified.  All frames listed in this section may be used in positive pressure assemblies per the terms and limitations of the individual listing.

 

All frames in this category are identified by a label or marking bearing the wording, "Listed Fire Door Frame", the Warnock Hersey Certification Mark, "UBC-7-2-97/UL-10C. Frames rated at less than 3 hours will have a time interval noted on the label/marking.  See Positive Pressure Section Header for more information.

 

Unless otherwise noted, assemblies in this section have also been tested to the following standards:

ASTM-E152, Methods of Fire Tests of Door Assemblies;

CAN/ULC-S104, Standard Method for Fire Tests of Door Assemblies;

CSFM-43.7, Methods of Fire Tests of Door Assemblies;

NFPA-252, Standard Methods of Fire Tests of Door Assemblies;

UBC-7-2-94, Uniform Building Code;

UL-10(b), Fire Tests of Door Assemblies;

and are installed, unless otherwise noted, in accordance with the following:

NFPA-80, Fire Doors & Windows.

Manufacturer's Instructions.

 

Listing Report Return to Search
Attributes
CriteriaASTM E152-81a
CriteriaUL 10(c) (1998)
CriteriaUBC 7-2 (1997)
CriteriaUBC 7-2 (1994)
CriteriaUL 10(b) (1997)
CriteriaASTM E2074 (2000)
CriteriaNFPA 252 (2003)
CriteriaCAN / ULC S104 (1980) (R1985)
CriteriaUL 10(c) (2009)
CriteriaUL 10(b) (2008) (R2009)
CriteriaCAN / ULC S104 (2010)
CriteriaNFPA 252 (2012)
CSI Code08 10 00 Doors and Frames
Fire Resistance20 Min PP Category C Proprietary Frame
Listing SectionCATEGORY C - PROPRIETARY FRAMES
Spec ID30087
SwingSingle Swing
SwingStandard Pairs
Design Documents
No Results
Public Documents