Intertek Directory of Building Products

Woodwork Manufacturing 20 Min Wood Fire Frame w/Hose Company: Woodwork Manufacturing & Supply, Inc.

Wood Door Frame (Douglas Fir) (Knock-Down) (Rabbeted Casing) (Applied T Stop) (Single or Double Rabbet) for installation in 20 minute locations (without hose stream) in steel/wood stud drywall openings.


Maximum Size of Openings: 4'0" wide x 9'0" high
Maximum Overall Dimensions: 51" wide x 109-1/2" high
Minimum Face: 1-1/4"
Minimum Wall Thickness: 2-7/8"
Minimum Jamb Depth: 3-13/16"


Note: Sidelights are not allowed with door pairs.
Wood Door Frame (Douglas Fir) (Knock-Down) (Applied T Stop) (Single or Double Rabbet) (Applied Casing) for installation in 20 minute locations in steel/wood stud drywall or masonry openings.


Maximum Size of Openings: Singles- 4'0" wide x 9'0" high
Pairs- 8'0" wide x 9'0" high
Maximum Overall Dimensions: Singles- 49-1/2" wide x 108-3/4" high
Pairs- 98-1/8" wide x 109-1/16" high
Minimum Wall Thickness and Minimum Jamb Depth: 3-3/4"
Minimum Frame Thickness: 3/4"


Note: Sidelights are not allowed with door pairs.

Evaluated to the following:

Unless otherwise noted, assemblies in this section have been tested to the following standards:
ASTM-E152, Methods of Fire Tests of Door Assemblies;
CAN/ULC-S104, Standard Method for Fire Tests of Door Assemblies;
NFPA-252, Standard Methods of Fire Tests of Door Assemblies;
UBC-7-2-94, Uniform Building Code;
UL-10(b), Fire Tests of Door Assemblies;
and are installed, unless otherwise noted, in accordance with the following:
NFPA-80, Fire Doors & Windows.
Manufacturer's Instructions.
Listed maximum sizes of lights are based on sizes tested and may exceed local code requirements.
All frames are identified by either a label or embossed marking bearing the wording "Listed (Product)" and the WHI Certification Mark. Frames rated for less than 3 hours also bear the time interval. Frame labels that do not include a time interval are rated for 3 hours.

Listing Report Return to Search
Attributes
CriteriaNFPA 252 (1995)
CriteriaASTM E152-81a
CriteriaUBC 7-2 (1994)
CriteriaUL 10(b) (1997)
CriteriaNFPA 80 (1995)
CriteriaCAN / ULC S104 (1980) (R1985)
CriteriaUL 10(b) 2008 (R2009)
CriteriaCAN / ULC S104 (2010)
CriteriaNFPA 252 (2012)
CSI Code08 10 00 Doors and Frames