AWIP fiRe Panel wall assemblies are constructed with a gypsum board sandwiched bonded between insulated steel-skin panels. The steel skins are available in 26, 24, or 22 GA Grade 33 steel conforming to ASTM A653 G90 galvanized, ASTM A792 AZ50 galvalume steel, or Stainless Steel 304 with 2B finish.
The overall nominal thickness of the wall panels is 4-1/2 inches, 5-1/2 inches or 6-1/2 inches. The profiles included in this Listing are: DM40-F, FL40-F, HE40-F, HE40A-F, ST40-F, MV40-F, and FW40-F.
RATINGS ACHIEVED
| Material |
Rating |
Design Number |
| ASTM E84 |
Flame Spread Index ≤ 25
Smoke Developed Index ≤ 450 |
NA |
| CAN/ULC S102 |
Flame Spread Index - 0
Smoke Developed Index - 5 |
NA |
| NFPA 286 |
Meets Requirements |
NA |
| CAN/ULC S138 |
Meets Requirements |
NA |
| NFPA 268 |
Meets Requirements |
NA |
| ASTM E119 |
1-Hour Rating |
AWIP/FWPA 60-02 |
| CAN/ULC S101 |
| NFPA 285 |
Meets Requirements |
AWIP/FWPA 30-03 |
| CAN/ULC S134 |
Meets Requirements |
AWIP/FWPA 25-03 |