Intertek Directory of Building Products

Gulfport Industries 45/90 Min & 3 Hour Hollow Metal Fire Doors Company: Gulfport Industries, Inc. (FL)

Hollow Metal Type (20 gauge) (Paper Honeycomb Core), Swinging Flush Design Fire Door with Transom Panel for installation in single swing 1-1/2 hour locations.
Limitations: Mortise and Cylindrical Latches/Surface Mounted Rim Type Fire Exit Hardware.
 
Maximum Size of Openings: Singles - 3'0" wide x 7'2" high
Transom Panel - 2'8" wide x 3'0" high

Hollow Metal Type (18 gauge) (Paper Honeycomb Core), Swinging Flush Design Fire Door for installation in single swing 1-1/2 hour locations.
Limitations: Mortise and Cylindrical Latches/Mortised and Surface Mounted Rim Type Fire Exit Hardware.
 
Maximum Size of Openings: Singles - 3'6" wide x 9'0" high

Hollow Metal Type (18 gauge) (Paper Honeycomb Core) (Stainless Steel), Swinging Flush Design Fire Door for installation in single swing 1-1/2 hour locations.
Limitations: Mortise and Cylindrical Latches/Mortised and Surface Mounted Rim Type Fire Exit Hardware.
 
Maximum Size of Openings: 3'0" wide x 7'2" high.

Hollow Metal Type (20 gauge) (Paper Honeycomb Core), Swinging Flush Design Fire Door for installation singly or in pairs, including double egress in 1-1/2 hour locations when equipped with a listed single point latch.
Limitations: Cylindrical Latches/Surface Mounted Vertical Rod Fire Exit Hardware/Surface Mounted Top and Bottom Bolts.
 
Maximum Size of Openings: Singles - 4'0" wide x 8'0" high
Pairs - 8'0" wide x 8'0" high
Double Egress - 8'0" wide x 8'0" high
Transom Panel - 8'0" wide x 2'0" high with Transom Bar

Hollow Metal Type (20 gauge) (Paper Honeycomb Core), Swinging Flush Design Fire Door for installation singly or in pairs in 1-1/2 hour locations.
Limitations: Mortise and/or Cylindrical Latches/Mortised and Surface Mounted Rim Type Fire Exit Hardware/Mortised and Surface Vertical Rod Fire Exit Hardware/Mortised and Surface Mounted Top and Bottom Bolts.
 
Maximum Size of Openings: Pairs - 8'0" wide x 8'0" high, Astragal required

Kalamein Type, Swinging Flush Design Fire Door for installation in single swing 1-1/2 hour locations.
Limitations: Cylindrical Latches.
 
Maximum Size of Openings: 3'0" wide x 7'0" high
Hollow Metal Type (20 gauge) (Paper Honeycomb Core), Swinging Flush Design Fire Door for installation in single swing 1-1/2 hour locations.
Limitations: Cylindrical Latches.
 
Maximum Size of Openings: 3'0" wide x 7'0" high

Hollow Metal Type (16, 18 gauge) (Steel-Stiffened) (Insulated or Paper Honeycomb Core), Swinging Flush Design Fire Door for installation singly or in pairs in 3 hour locations.
Limitations: Mortise and Cylindrical Latches/Mortised and Surface Mounted Top and Bottom Bolts.
 
Maximum Size of Openings: Singles - 4'0" wide x 8'0" high
Pairs - 8'0" wide x 8'0" high, Astragal required

Hollow Metal Type (20 gauge) (Paper Honeycomb Core), Swinging Flush Design Fire Door for installation singly or in pairs in 1-1/2 hour locations.
Limitations: Cylindrical Latches/Mortised and Surface Mounted Top and Bottom Bolts.
 
Maximum Size of Openings: Singles - 3'0" wide x 7'2" high
Pairs - 6'0" wide x 7'2" high, Astragal Required

Note: For additional information please refer to the Pyrophobic Systems Ltd. listing.
Other Locations
Mississauga, ON
CANADA L4V 1P3.

Evaluated to the following:
Unless otherwise noted, assemblies in this section have been evaluated for conformance to the following standards:
ASTM-E152, Methods of Fire Tests of Door Assemblies
CAN/ULC-S104, Standard Method for Fire Tests of Door Assemblies
NFPA-252, Standard Methods for Fire Tests of Door Assemblies
UBC-7-2-94, Uniform Building Code
UL-10(b), Fire Tests of Door Assemblies
and are installed in accordance with the following:
NFPA-80, Fire Doors and Windows

Manufacturer's Instructions.
All assemblies are identified by a label or marking bearing the wording, "Listed (Product)", a time interval, temperature rise (if applicable), a serial number and the WHI Certification Mark.
(Unless otherwise specified, all Fire Doors have a nominal thickness of 1-3/4".)
 
Listing Report Return to Search
Attributes
CriteriaNFPA 252 (1995)
CriteriaASTM E152-81a
CriteriaUBC 7-2 (1994)
CriteriaUL 10(b) (1997)
CriteriaCAN / ULC S104 (1980) (R1985)
CriteriaUL 10(b) 2008 (R2009)
CriteriaCAN / ULC S104 (2010)
CriteriaNFPA 252 (2012)
CSI Code08 11 00 Metal Doors and Frames
Fire Resistance45 Min Neutral Pressure
Fire Resistance90 Min Neutral Pressure
Fire Resistance3 Hour Neutral Pressure
Fire Resistance60 Min Neutral Pressure
Listing SectionDOORS
Spec ID30278
SwingSingle Swing
SwingStandard Pairs
SwingDouble Egress
Design Documents
No Results
Public Documents
No Results