Intertek Directory of Building Products

A&L Shielding - 60 Min Lead Lined CoreClad™ Fire Door Company: A & L Shielding, Inc.

Mineral Core Type, Single Lead Lined CoreClad™ Door Assembly with lead lined vision panel and mortise lock. Mineral core Standard Pair Lead Lined CoreClad™ Door Assembly with lead lined metal edge and astragal set. For use in listed (3-sided) 16 gauge welded steel frames meeting ASNI A155.1/UL63 or as per frame manufacturer's listing(s). No additional edge-sealing system is required.
Maximum Sizes
Single                4'0" x 8'0"
Standard Pairs    8'0" x 8'0"
Double Egress    Not Allowed
3 or 4 Point Latching Required
Limitations*
Mortise (Single Only) or Cylindrical Latches with maximum 5" backset / Surface-Mounted Vertical Rod Fire Exit Devices / Rim-Type Fire Exit Devices / Cylindrical and Mortise Deadbolts / Surface Bolts / Mortised Automatic Flushbolts / Surface-Mounted Closers / Surface-Mounted Protection Plates / Viewer / Surface-Mounted Door Bottoms / Metal Edges Required / Astragal Required with 3-Point Latching / Electric Raceway / Temperature Rise - 250 degrees Farenheit at 30 Minutes.
*See manufacturer's installation instructions for additional information on Smoke and Draft Control, size restrictions, and limitations.
Listing Report Certificate of Compliance Return to Search
Attributes
Certificate Date of ExpiryDecember 31, 2026
Certificate Date of Initial RegistrationOctober 1, 2016
Certificate NumberWHI16 – 20362301
CriteriaASTM E152-81a
CriteriaUL 10(c) (1998)
CriteriaUBC 7-2 (1997)
CriteriaNFPA 252 (1999)
CriteriaUL 10(c) (2009)
CriteriaNFPA 252 (2012)
CSI Code08 34 00 Special Function Doors
CSI Code08 31 00 Access Doors and Panels
Fire Resistance60 Min PP Category A Door
Frame OptionsSteel
Listing SectionCATEGORY A - DOORS - NO ADDITIONAL EDGE-SEALING SYSTEM REQUIRED
Spec ID30296
SwingSingle Swing
SwingStandard Pairs
SwingLead Lined
Temperature Rise@ 30 Min = 250° F MAX Where Lites Do Not Exceed 100 IN2
Design Documents
No Results
Public Documents
No Results