PRODUCT COVERED
60 Minute Fire Door Frame
PRODUCT DESCRIPTION
Category C "Proprietary Frame" - Composite Door Frame for installation in 60 minute locations in steel/wood stud drywall or masonry openings. A Category B or Neutral Pressure fire rated wood/composite door may be used. Category G Edge Sealing System is not required. May be veneered or faced with HPL. Frame may also be used as a communicating frame.
Maximum Sizes
Single-Swing: 48 in. wide by 96 in. high
Throat Opening: 4-3/4 in.
RATINGS
60 minute Neutral Pressure or Positive Pressure Fire Rating
EVALUATED TO THE FOLLOWING
Unless otherwise noted, assemblies in this section have been tested to the following standards:
ASTM E2074(2000) and ASTM-E152, Methods of Fire Tests of Door Assemblies;
CAN/ULC-S104, Standard Method for Fire Tests of Door Assemblies;
CSFM-43.7, Methods of Fire Tests of Door Assemblies;
NFPA-252, Standard Methods of Fire Tests of Door Assemblies;
UBC-7-2-94, Uniform Building Code;
UBC-7-2(1997) Part I
UL-10(b),and UL-10(c) Fire Tests of Door Assemblies;
and are installed, unless otherwise noted, in accordance with the following:
NFPA-80, Fire Doors & Windows.
Manufacturer's Instructions.
All frames are identified by either a label or embossed marking bearing the wording "Listed (Product)" and the WHI Certification Mark.