PRODUCT COVERED
20 Minute Fire Door Frame
PRODUCT DESCRIPTION
Category C "Proprietary Frame" - Composite Door Frame for installation in 20 minute locations in steel/wood stud drywall or masonry openings. A Category B or Neutral Pressure fire rated wood/composite door may be used. Category G Edge Sealing System is not required. May be veneered or faced with HPL. Frame may also be used as a communicating frame. Concealed closer allowed.(LCN 2030 Series)
Maximum Sizes
Single-Swing: 48 in. wide by 96 in. high
Pair: 84 in. wide by 96 in. high
Throat Opening: 4-3/4 in.
RATINGS
20 minute Neutral Pressure Fire Rating, with hose stream
EVALUATED TO THE FOLLOWING
Unless otherwise noted, assemblies in this section have been tested to the following standards:
ASTM E2074(2000) and ASTM-E152, Methods of Fire Tests of Door Assemblies;
CAN/ULC-S104, Standard Method for Fire Tests of Door Assemblies;
NFPA-252, Standard Methods of Fire Tests of Door Assemblies;
UBC-7-2-94, Uniform Building Code;
UL-10(b) Fire Tests of Door Assemblies;
and are installed, unless otherwise noted, in accordance with the following:
NFPA-80, Fire Doors & Windows.
Manufacturer's Instructions.
All frames are identified by either a label or embossed marking bearing the wording "Listed (Product)" and the WHI Certification Mark.