PRODUCT COVERED
20 Minute Fire Door Frame
PRODUCT DESCRIPTION
Category C "Proprietary Frame" - Composite Door Frame for installation in 20 minute locations in steel/wood stud drywall or masonry openings. A Category B or Neutral Pressure fire rated wood/composite door may be used. Category G Edge Sealing System is not required. May be veneered or faced with HPL. Frame may also be used as a communicating frame.
Maximum Sizes
Single-Swing: 48 in. wide by 96 in. high
Pair: 84 in. wide by 96 in. high
Throat Opening: 4-3/4 in.
RATINGS
20 minute Neutral Pressure or Positive pressure Fire Rating, with hose stream
EVALUATED TO THE FOLLOWING
Unless otherwise noted, assemblies in this section have been tested to the following standards:
ASTM E2074(2000) and ASTM-E152, Methods of Fire Tests of Door Assemblies;
CAN/ULC-S104, Standard Method for Fire Tests of Door Assemblies;
CSFM-43.7, Methods of Fire Tests of Door Assemblies;
NFPA-252, Standard Methods of Fire Tests of Door Assemblies;
UBC-7-2-94, Uniform Building Code;
UBC-7-2(1997) Part I
UL-10(b),and UL-10(c) Fire Tests of Door Assemblies;
and are installed, unless otherwise noted, in accordance with the following:
NFPA-80, Fire Doors & Windows.
Manufacturer's Instructions.
All frames are identified by either a label or embossed marking bearing the wording "Listed (Product)" and the WHI Certification Mark.