Pressed Steel Door Frame (16 gauge) (Knock-Down) for installation in 3 hour locations in steel/wood stud drywall or masonry openings, including double egress.
 
Maximum Size of Openings: 8'4-3/8" wide x 10'0" high
Maximum Overall Dimensions: 105" wide x 124" high
Minimum Throat Opening: 3-1/2" (2" with 20 minute rating)

 
Pressed Steel Door Frame (Double Egress) (12, 14, or 16 gauge) (Welded Up) for installation in 1-1/2 hour locations in steelwood stud drywall or masonry openings.
 
Maximum Size of Openings: 8'4-3/8" wide x 9'0" high
Maximum Overall Dimensions: 104-3/8" wide x 110" high
Minimum Throat Opening: 3-1/2"

 Pressed Steel Side Light Door Frame (14, 16 gauge) (Welded Up) for installation in 1 hour locations in steel/wood stud drywall or masonry openings.
Limitations: "Firelight" listed glazing (or equivalent) must be used, and prior approval must be obtained from the authority having jurisdiction, as applicable code requirements may vary. All listing conditions for the glazing must be satisfied.
 
Maximum Overall Dimensions: 10'2" wide x 10'1" high
Minimum Wall Thickness: 4-7/8"
Maximum Clear View Glazing Area: 2.721 sq.in.
Stop Height: 5/8"
 
 
Pressed Steel Side Light Door Frame (16 gauge)(Welded Sections or Fully Welded or KD) for installation in 45 minute locations in steel/wood stud drywall or masonry openings.
Limitations: Side Lights require Pemko FG 3000 Compound and Pilkington Glass. Prior approval must be obtained from the authority having jurisdiction, as applicable code requirements may vary. All the listing conditions for the glazing must be satisfied.
 
Total Maximum Width: 12'8" Drywall; 13'6" Masonry Wall
Total Maximum Height: 11'4" Drywall; 12'0" Masonry Wall
Minimum Side Light Stop Height: 5/8"
Minimum Throat Opening 5-3/4"
 
 
Pressed Steel Door Frame "FR100" (12, 14, or 16 gauge) (Welded) for installation in 1-1/2 hour locations in steel/wood stud drywall or masonry openings, including double egress.
 
Singles: 4'0" wide x 8'0" high
Standard Pairs (including Double Egress):  8'0" wide x 8'0" high
Minimum Throat Opening: 4"
 
Pressed Steel Door Frame "FR200" (Double Egress) (12, 14, or 16 gauge) for installation in 1-1/2 hour locations in steelwood stud drywall or masonry openings.
 
Singles: 4'0" wide x 8'0" high
Standard Pairs (including Double Egress):  8'0" wide x 8'0" high
Minimum Wall Thickness: 4"
*NOTE: Door height of 10'0" is allowed with 18 gauge buck.
 
Listing Report Return to Search
Attributes
CriteriaUL 10(b) 2008 (R2009)
CriteriaCAN / ULC S104 (2010)
CriteriaNFPA 252 (2012)
CriteriaCAN / ULC S104 (2015) (R2020)
CriteriaUL 10(c) (2016)
CSI Code08 11 00 Metal Doors and Frames
Fire Resistance20 Min NP Fire Doorframe
Fire Resistance45 Min NP Fire Doorframe
Fire Resistance60 Min NP Fire Doorframe
Fire Resistance3 Hour NP Fire Doorframe
Fire Resistance90 Min NP Fire Doorframe
Fire Resistance20 Min w/Hose Positive Pressure
Fire Resistance45 Min Positive Pressure
Fire Resistance90 Min Positive Pressure
Fire Resistance60 Min Positive Pressure
Fire Resistance3 Hour Positive Pressure