Pressed Steel Door Frame (16 gauge) (Welded Up) with Raised Side Light and/or Removable Steel Transom and Head/Transom Mullion for installation in 3/4 hour locations in steel/wood stud drywall or masonry openings.
Maximum Size of Door Openings:
|
6'0" wide x 7'0" high
|
Maximum Size of Steel Transom:
|
6'0" wide x 2'0" high
|
Maximum Size of Raised (Hinge Side) Light:
|
2,500 sq.in. with clear width not to exceed 50"
|
Maximum Overall Dimensions:
|
12'6" (150") wide x 10'0" high |
Minimum Wall Thickness: |
3-3/4" |
Note: Oversized lights (per NFPA 80) require special listed glazing and glazing compound.
Evaluated to the following:
Unless otherwise noted, assemblies in this section have been tested to the following standards:
ASTM-E152, Methods of Fire Tests of Door Assemblies;
CAN/ULC-S104, Standard Method for Fire Tests of Door Assemblies;
NFPA-252, Standard Methods of Fire Tests of Door Assemblies;
UBC-7-2-94, Uniform Building Code;
UL-10(b), Fire Tests of Door Assemblies;
UL-10(c), Positive Pressure Fire Tests of Door Assemblies;
and are installed, unless otherwise noted, in accordance with the following:
NFPA-80, Fire Doors & Windows.
Manufacturer's Instructions.
Listed maximum sizes of lights are based on sizes tested and may exceed local code requirements.
All frames are identified by either a label or embossed marking bearing the wording "Listed (Product)" and the WHI Certification Mark. Frames rated for less than 3 hours also bear the time interval. Frame labels that do not include a time interval are rated for 3 hours.