Hollow Metal Type (Steel-Faced) (14, 12, 10 gauge) (Steel-Stiffened), Swinging Flush Design Fire Door and Pressed Steel (Welded up) (14, 12, 10 gauge) Door/Frame Assembly for installation in single swing 3 hour locations in masonry where restricted and/or remote controlled egress is permitted.
Limitations
Remote Manual or Electro-Mechanical Rotary Latches/Manual or Key-Operated Latches/Door Guards/Institutional Hinges/Meets Static and Rack Load requirement to NAAMM Standard HMMA 863-87 with doors 2" thick and 12 gauge steel faces.
Maximum Overall Dimensions: 42" wide x 86" high
Maximum Size of Openings: 3'0" wide x 7'0" high
Minimum Throat Opening: 2"
Fabrication Standard: UL-63
Hollow Metal Type (Steel Faced & Steel Stiffened) (12, 14, 16 gauge) Swinging Flush Design Fire Door and Pressed Steel (Welded up) (10, 12, 14 gauge) Door/Frame Assembly for installation in single swing 3 hour locations in masonry walls where restricted and/or remote controlled egress is permitted
Limitations
Remote Manual or Electro-Mechanical Rotary Latches/Manual or Key-Operated Latches/Door Guards/Institutional Hinges/Meets Static and Rock Load requirement to NAAMM Standard HMMA 863-87.
Configuration Maximum Size
Single Swing 4'0" wide x 8'0" high
Hollow Metal Type (Steel-Faced) (14, 12, 10 gauge) (Steel-Stiffened), Swinging Flush Design Fire Door and Pressed Steel (Welded up) (14, 12, 10 gauge) Door/Frame Assembly for installation in single swing and standard pairs 90 minute locations in masonry where restricted and/or remote controlled egress is permitted.
Limitations
Remote Manual or Electro-Mechanical Rotary Latches/Manual or Key-Operated Latches/Door Guards/Institutional Hinges/Meets Static and Rack Load requirement to NAAMM Standard HMMA 863-87 with doors 2" thick and 12 gauge steel faces. 3/4" Astragal must be applied to standard pairs.
Configuration Maximum Size
Single Swing 5'0" wide x 12'0" high
Standard Pairs 10'0" wide x 12'0" high