Intertek Directory of Building Products

Titan Metal 20 Min - 3 Hour (Single Swing/Standard Pair/Double Egress) Fire Frames (Fully Welded) Company: Titan Metal Products, Inc.

DOOR FRAMES
Pressed Steel Door Frame (16 gauge) (Welded Up) (Single Swing & Standard Pairs) for installation in 20 minute to 3 hour locations in steel/wood stud drywall or masonry openings.  Stainless steel optional.
 
Maximum Size of Openings: 8'-0" wide x 10'-0" high
Maximum Overall Dimensions: 8'-8" wide x 10'-4" high
Minimum Wall Thickness and Throat Opening: 3"

Pressed Steel Door Frame (16 gauge) (Welded Up) (Double Egress) for installation in 20 minute to 3 hour locations in steel/wood stud drywall or masonry openings.  Stainless steel optional.
 
Maximum Size of Openings: 8'-0" wide x 10'-0" high
Maximum Overall Dimensions: 8'-8" wide x 10'-4" high
Minimum Wall Thickness and Throat Opening: 3-1/4"

Evaluated to the following:
Unless otherwise noted, assemblies in this section have been tested to the following standards:
CAN/ULC-S104, Standard Method for Fire Tests of Door Assemblies;
NFPA-252, Standard Methods of Fire Tests of Door Assemblies;
UL-10(b), Fire Tests of Door Assemblies;
UL-10(c), 
Standard for Positive Pressure Fire Tests of Door Assemblies and are installed, unless otherwise noted, in accordance with the following:
NFPA-80, Fire Doors & Windows.

Manufacturer's Instructions.
Listed maximum sizes of lights are based on sizes tested and may exceed local code requirements.
All frames are identified by either a label or embossed marking bearing the wording "Listed (Product)" and the WHI Certification Mark. Frames rated for less than 3 hours also bear the time interval. Frame labels that do not include a time interval are rated for 3 hours.
CATEGORY C - PROPRIETARY FRAMES
Pressed Steel Door Frame (16 gauge) (Welded-Up) (Single Swing & Standard Pair) for installation in 20 minutes to 180 minute locations in Steel/Wood Stud Drywall, Masonry Openings. Also tested to: UBC-43-7.
 
Max. Size of Openings: 8'-0" wide x 10'-0" high
Max. Overall Dimensions: 8'-8" wide x 10'-4" high
Min. Wall Thickness and Throat Opening: 3"

Pressed Steel Door Frame (16 gauge) (Welded-Up) (Double Egress) for installation in 20 minute to 180 minute locations in Steel/Wood Stud Drywall, Masonry Openings.
 
Max. Size of Openings: 8'-0" wide x 10'-0" high
Max. Overall Dimensions: 8'-8" wide x 10'-4" high
Min. Wall Thickness and Throat Opening: 3-1/4"

Evaluated to the following:
This category includes frames not based on UL-63 construction Type (such as aluminum, wood, light gauge steel, composite, etc.). These listings will reference specific door types for which each frame is qualified. All frames listed in this section may be used in positive pressure assemblies per the terms and limitations of the individual listing.
All frames in this category are identified by a label or marking bearing the wording, "Listed Fire Door Frame", the Warnock Hersey Certification Mark, UL-10C. Frames rated at less than 3 hours will have a time interval noted on the label/marking. See Positive Pressure Section Header for more information.
Listing Report Return to Search
Attributes
CriteriaUL 10(b) 2008 (R2009)
CriteriaUL 10(c) (2009)
CriteriaCAN / ULC S104 (2010)
CriteriaNFPA 252 (2012)
CriteriaCAN / ULC S104 (2015) (R2020)
CriteriaUL 10(c) (2016)
CriteriaNFPA 252 (2017)
CSI Code08 11 00 Metal Doors and Frames
Fire Resistance20 Min PP Category C Proprietary Frame
Fire Resistance20 Min NP Fire Doorframe
Fire Resistance45 Min PP Category C Proprietary Frame
Fire Resistance3 Hour PP Category C Proprietary Frame
Fire Resistance45 Min NP Fire Doorframe
Fire Resistance60 Min NP Fire Doorframe
Fire Resistance3 Hour NP Fire Doorframe
Fire Resistance90 Min NP Fire Doorframe
Fire Resistance60 Min PP Category C Proprietary Frame
Fire Resistance90 Min PP Category C Proprietary Frame
Listing SectionCATEGORY C - PROPRIETARY FRAMES
Listing SectionDOOR FRAMES
Spec ID31498
SwingSingle Swing
SwingStandard Pairs
SwingDouble Egress
Design Documents
No Results
Public Documents
No Results