Steel-Faced (18 gauge) (Foam Core) Swinging Flush Door for installation in 1-1/2 hour locations. For use in listed (3-sided) 16 gauge welded steel frames meeting ANSI-A155.1/UL-63 or per framed manufacturer's listing(s).
Limitations*
Mortise or Cylindrical latches with 2-3/4" Backset and minimum 3/4" Bolt Throw / Rim-Type Fire Exit Devices / Deadbolts / Surface-Mounted Closers / Surface-Mounted Protection Plates / Vision Lite Kit - Max 100 sq. in.
Maximum Sizes
Single Swing 3'0" x 7'2"
Standard Pairs Not Allowed
*See manufacturer's installation instructions for additional information on Smoke and Draft Control, size restrictions and limitations.
Evaluated to the following...
This category includes doors evaluated without an edge-sealing system between the door and frame. It also includes doors evaluated with a sealing system incorporated (concealed or visible) into the edge of the door by the licensed manufacturer or machining distributor.
Meeting edges of pairs may require an astragal or an edge-sealing system. Please refer to individual door listings.
These doors are eligible for use in any "Category C - Standard" frame. These doors may also be installed in frames listed in "Category C - Proprietary" in the accordance with the frame manufacturer's individual listing.
All doors listed in Category A are eligible to bear the "S" (for Smoke & Draft Control assemblies) if a listed "Category H - Smoke & Draft Control Gasket" has been applied to the assembly. Please refer to Category H for individual gasket manufacturer's listings.
All doors in this category are identified by a label or marking bearing the wording, "Listed Fire Door", a time interval, a temperature rise rating, a serial number and the Warnock Hersey Certification Mark and "UBC-7-2-97/UL 10C".