Therma Tru 90 Min Hollow Metal Fire Door PP Model 90PPHMFD Company: Therma Tru Corporation

Hollow Metal Type (16, 18, 20, gauge) (Steel-Faced) (Foam-Filled), Swinging Flush or Embossed Design Fire Door for installation in single swing 1-1/2 hour locations.

Limitations

Cylindrical Latches/Deadbolts/4-1/2" x 4-1/2" x 0.134" Hinges.

Maximum Size of Openings

Single Swing     3'0" wide x 7'0" high 

Hollow Metal Type (18, 20 gauge) (Steel-Faced) (Polystyrene Foam-Filled), Swinging Flush Design Fire Door for installation in single swing 1-1/2 hour locations.

Limitations

Mortise or Cylindrical Latches/4" x 4" x 0.097" Hinges.

Maximum Size of Openings

Single Swing     3'0" wide x 7'0" high  

Evaluated to the Following
Unless otherwise noted, assemblies in this section have been evaluated for conformance to the following standards:
ASTM-E152, Methods of Fire Tests of Door Assemblies
CSFM-43.7, Methods of Fire Tests of Door Assemblies
CAN4-S104(ULC-S104), Standard Method for Fire Tests of Door Assemblies
NFPA-252, Standard Methods for Fire Tests of Door Assemblies
UBC-7-2-97, Uniform Building Code
UL-10(c), Fire Tests of Door Assemblies
and are installed in accordance with the following:
NFPA-80, Fire Doors and Windows
Manufacturer's Instructions.
All assemblies are identified by a label or marking bearing the wording, "Listed (Product)", a time interval, temperature rise (if applicable), a serial number and the WHI Certification Mark.
(Unless otherwise specified, all Fire Doors have a nominal thickness of 1-3/4".)
Listing Report Return to Search
Attributes
CriteriaNFPA 80 (1999)
CriteriaNFPA 252 (1995)
CriteriaASTM E152-81a
CriteriaUL 10(c) (1998)
CriteriaCSFM 43.7
CriteriaUBC 7-2 (1997)
CriteriaUL 10(c) (2009)
CriteriaNFPA 252 (2012)
CSI Code08 11 00 Metal Doors and Frames
CSI Code08 11 13 Hollow Metal Doors and Frames
Fire Resistance90 Min Positive Pressure