The model Jotul GF 200 DV IPI direct vent gas fireplace heater is a freestanding appliance. It is equipped and operated with an intermittent pilot and direct spark ignition system. The unit front contains a glass panel for viewing the flame and simulated wood logs.
Natural Gas Propane Gas
Input rating (Btu/hr) 0-610 m 20,000 18,000
Maximum output (Btu/hr) 0-610 m 13,700 12,200
Minimum input (Btu/hr) 0-610 m 11,000 9,000
Orifice size (DMS) 0-610 m 2.1 mm 1.2 mm
Input rating (Btu/hr) 610-1370 m 19,600 16,900
Orifice size (DMS) 610-1370 m 46 56
Manifold pressure (in. w.c./kPa) 3.8/0.95 11.0/2.74
Manifold pressure, Low setting
(in. w.c./kPa) 1.1/0.27 2.9/0.72
Minimum inlet pressure
(in. w.c./kPa) 5.0/1.25 12/3.0
Steady State Efficiency (%) 75.16 73.56
AFUE Efficiency (%) 68.6 68.2
Air shutter setting (in) 1/16 1/8