Intertek Directory of Building Products

Taylor Entrance Systems Economy 20-90 Min w/hose Hollow Metal Fire Door PP Company: Taylor Entrance Systems

Positive Pressure Category B Doors – Additional Edge Sealing System Required
Taylor Entrance Systems Economy Steel-Faced (18, 20, 22, & 24 gauge) (Urethane Core) (Simulated Panel or Flush Type) Swinging Flush Door for installation in up to 90 minute locations. For use in any "Category C - Standard frame. These doors may also be installed in frames listed in "Category C - Proprietary" in accordance with the frame manufacturer's individual listing. A field-applied edge seal system is required. Refer to the individual manufacturer's Category G listing for limitations.

Limitations*
Mortise or Cylindrical Latches with maximum 5" Backset/Mortised Exit Devices/Surface Mounted Vertical Rod Fire Exit Devices/Rim-Type Fire Exit Devices/Deadbolts/Surface-Mounted Closers/Viewer/Surface-Mounted Door Bottoms. Temperature Rise - 650°F at 30 minutes.
 
Maximum Sizes
Single Swing 3’-6” wide by 7’-0” high (22 & 24 gauge only)
4’-0” wide by 8’-0” high (18 & 20 gauge only)
Standard Pairs Not Allowed
Double Egress Pairs Not Allowed

*See manufacturer's installation instructions for additional information on Smoke and Draft Control, size restrictions and limitations.
Testing Standard: UL-10C (Positive Pressure).
 
Evaluated to the following...
This category includes doors evaluated with an edge-sealing system (Category G) field-applied to the labeled frame or door. The application of the edge-sealing system does not require any machining of the frame or door. Please refer to "Category G - Edge-Sealing System" for individual manufacturer's listings.
 
These assemblies are eligible for use in any "Category C - Standard" frame. These doors may also be installed in frames listed in "Category C - Proprietary" in the accordance with the frame manufacturer's individual listing.
 
All doors listed in Category B are eligible to bear the "S" (for Smoke & Draft Control assemblies) if a listed "Category H - Smoke & Draft Control Gasket" has been applied to the assembly. Please refer to Category H for individual gasket manufacturer's listings.
 
All doors in this category are identified by a label or marking bearing the wording, "Listed Fire Door", a time interval, a temperature rise rating, a serial number, and the Warnock Hersey Certification Mark and "UL 10C".

Models and Descriptions
  Perma Door Taylor Door
Light Gauge Door Economy Economy
Adjustable Hinge Royal Uni-Dor
Fixed Hinge Simplicity DuraDoor
Stainable Steel Regency Regal
Listing Report Return to Search
Attributes
CriteriaCAN / ULC S104 (2015) (R2020)
CriteriaUL 10(c) (2016) Ed. 3 (R:27 May 2021)
CriteriaNFPA 252 (2022)
CSI Code08 11 13 Hollow Metal Doors and Frames
Fire Resistance45 Min Positive Pressure
Fire Resistance90 Min Positive Pressure
Fire Resistance60 Min Positive Pressure
Fire Resistance20 Min Positive Pressure
Listing SectionCATEGORY B - DOORS - ADDITIONAL EDGE-SEALING SYSTEM REQUIRED
Spec ID32675
SwingSingle Swing
Temperature Rise@ 30 Min = 650° F MAX Where Lites Do Not Exceed 100 IN2
Design Documents
No Results
Public Documents