Intertek Directory of Building Products

Taylor Entrance Systems Economy 20-90 Min w/hose Hollow Metal Fire Door NP Company: Taylor Entrance Systems

Neutral Pressure Doors
Economy Entrance Systems Steel-Faced (18, 20, 22, and 24 gauge) (Urethane Core Type) Swinging Flush Door for installation in 1-1/2 hour locations. For use in listed 3-sided frames as per frame manufacturer's listing(s)

Limitations*
Mortise or Cylindrical Latches with maximum 2-3/4" backset/Mortised Exit devices/Surface Mounted Vertical Rod Fire Exit Devices/Rim Type Fire Exit Devices/Deadbolts/Surface Mounted Closers/Surface Mounted Protection Plates/Viewer/Vision Light Kit - Maximum 792 in2 (1/3, 3/4 hour) or 100 in2 (1, 1-1/2 hour)/Gasketing - listed and labeled for opening/ Listed Fusible Link Louver - Maximum 576 in2 (3/4 hour)/ Gasketing - listed and labeled for opening.
Note: Louvers are not allowed in smoke and draft(S) doors.
 
Maximum Size
Single Swing 3’-6” wide by 7’-0” high (22 & 24 gauge only)
4’-0” wide by 8’-0” high (18 & 20 gauge only)
Standard Pairs Not Allowed
Double Egress Pairs Not Allowed
*See Manufacturer's installation instructions for additional information on size restrictions and limitations  

Taylor Economy and Perma-Door Economy Faced (18, 20, 22, & 24 gauge) Swinging Flush Door for installation in 1-1/2 hour locations. For use in listed 3-sided frames as per frame manufacturer's listing(s).

Limitations*
Mortise or Cylindrical Latches with maximum 2-3/4" backset/Mortised Exit devices/Surface Mounted Vertical Rod Fire Exit Devices/Rim Type Fire Exit Devices/Deadbolts/Surface Mounted Closers/Surface Mounted Protection Plates/Viewer/Vision Light Kit - Maximum 792 sq.in (1/3, 3/4 hour) or 100 sq.in. (1, 1-1/2 hour)/Gasketing - listed and labeled for opening.
 
Maximum Size
Single Swing 3’-6” wide by 7’-0” high (22 & 24 gauge only)
4’-0” wide by 8’-0” high (18 & 20 gauge only)
Standard Pairs Not Allowed
Double Egress Pairs Not Allowed
* See Manufacturer's installation instructions for additional information on size restrictions and limitations.

Evaluated to the following...
Unless otherwise noted, assemblies in this section have been evaluated for conformance to the following standards:
  • ASTM-E152, Methods of Fire Tests of Door Assemblies
  • CSFM-43.7, Methods of Fire Tests of Door Assemblies
  • CAN4-S104(ULC-S104), Standard Method for Fire Tests of Door Assemblies
  • NFPA-252, Standard Methods for Fire Tests of Door Assemblies
  • UL-10(b), Fire Tests of Door Assemblies
and are installed in accordance with the following:
  • NFPA-80, Fire Doors and Windows
Manufacturer's Instructions
All assemblies are identified by a label or marking bearing the wording, "Listed (Product)", a time interval, temperature rise (if applicable), a serial number and the WHI Certification Mark.
 
(Unless otherwise specified, all Fire Doors have a nominal thickness of 1-3/4".)

Models and Descriptions
  Perma Door Taylor Door
Light Gauge Door Economy Economy
Adjustable Hinge Royal Uni-Dor
Fixed Hinge Simplicity DuraDoor
Stainable Steel Regency Regal
Listing Report Return to Search
Attributes
CriteriaCAN / ULC S104 (2015) (R2020)
CriteriaUL 10(b) (2008) (R2020)
CriteriaNFPA 252 (2022)
CSI Code08 11 13 Hollow Metal Doors and Frames
Fire Resistance45 Min Neutral Pressure
Fire Resistance90 Min Neutral Pressure
Fire Resistance20 Min w/Hose Stream NP
Fire Resistance60 Min Neutral Pressure
Listing SectionDOORS
Spec ID32676
SwingSingle Swing
Temperature Rise@ 30 Min = 650° F MAX Where Lites Do Not Exceed 100 IN2
Design Documents
No Results
Public Documents
No Results