Neutral Pressure Doors
Economy Entrance Systems Steel-Faced (18, 20, 22, and 24 gauge) (Urethane Core Type) Swinging Flush Door for installation in 1-1/2 hour locations. For use in listed 3-sided frames as per frame manufacturer's listing(s)
Limitations*
Mortise or Cylindrical Latches with maximum 2-3/4" backset/Mortised Exit devices/Surface Mounted Vertical Rod Fire Exit Devices/Rim Type Fire Exit Devices/Deadbolts/Surface Mounted Closers/Surface Mounted Protection Plates/Viewer/Vision Light Kit - Maximum 792 in
2 (1/3, 3/4 hour) or 100 in
2 (1, 1-1/2 hour)/Gasketing - listed and labeled for opening/ Listed Fusible Link Louver - Maximum 576 in
2 (3/4 hour)/ Gasketing - listed and labeled for opening.
Note: Louvers are not allowed in smoke and draft(S) doors.
Maximum Size |
Single Swing |
3’-6” wide by 7’-0” high (22 & 24 gauge only) |
4’-0” wide by 8’-0” high (18 & 20 gauge only) |
Standard Pairs |
Not Allowed |
Double Egress Pairs |
Not Allowed |
*See Manufacturer's installation instructions for additional information on size restrictions and limitations
Taylor Economy and Perma-Door Economy Faced (18, 20, 22, & 24 gauge) Swinging Flush Door for installation in 1-1/2 hour locations. For use in listed 3-sided frames as per frame manufacturer's listing(s).
Limitations*
Mortise or Cylindrical Latches with maximum 2-3/4" backset/Mortised Exit devices/Surface Mounted Vertical Rod Fire Exit Devices/Rim Type Fire Exit Devices/Deadbolts/Surface Mounted Closers/Surface Mounted Protection Plates/Viewer/Vision Light Kit - Maximum 792 sq.in (1/3, 3/4 hour) or 100 sq.in. (1, 1-1/2 hour)/Gasketing - listed and labeled for opening.
Maximum Size |
Single Swing |
3’-6” wide by 7’-0” high (22 & 24 gauge only) |
4’-0” wide by 8’-0” high (18 & 20 gauge only) |
Standard Pairs |
Not Allowed |
Double Egress Pairs |
Not Allowed |
* See Manufacturer's installation instructions for additional information on size restrictions and limitations.
Evaluated to the following...
Unless otherwise noted, assemblies in this section have been evaluated for conformance to the following standards:
- ASTM-E152, Methods of Fire Tests of Door Assemblies
- CSFM-43.7, Methods of Fire Tests of Door Assemblies
- CAN4-S104(ULC-S104), Standard Method for Fire Tests of Door Assemblies
- NFPA-252, Standard Methods for Fire Tests of Door Assemblies
- UL-10(b), Fire Tests of Door Assemblies
and are installed in accordance with the following:
- NFPA-80, Fire Doors and Windows
Manufacturer's Instructions
All assemblies are identified by a label or marking bearing the wording, "Listed (Product)", a time interval, temperature rise (if applicable), a serial number and the WHI Certification Mark.
(Unless otherwise specified, all Fire Doors have a nominal thickness of 1-3/4".)
Models and Descriptions
|
Perma Door |
Taylor Door |
Light Gauge Door |
Economy |
Economy |
Adjustable Hinge |
Royal |
Uni-Dor |
Fixed Hinge |
Simplicity |
DuraDoor |
Stainable Steel |
Regency |
Regal |