Panel Type (Proprietary Construction) Wood Fire Door for installation singly in 20 minute without Hose locations for use in any "Category C - Standard" frame. A field applied edge-sealing system is required. Refer to the door manufacturer's installation instructions for edge-sealing system requirements.
Limitations: Cylindrical or Mortise latches with minimum 1/2" bolt throw and 2-3/4" backset/Surface Mounted vertical rod fire exit hardware/Surface mounted Bolts/Surface Mounted Closer.
Configuration
|
Maximum Size
|
Single Swing |
3'6" wide x 8'0" high |
Evaluated to the following:
This category includes doors evaluated with an edge-sealing system (Category G) field-applied to the labeled frame or door. The application of the edge-sealing system does not require any machining of the frame or door. Please refer to "Category G - Edge-Sealing System" for individual manufacturer's listings.
These assemblies are eligible for use in any "Category C - Standard" frame. These doors may also be installed in frames listed in "Category C - Proprietary" in the accordance with the frame manufacturer's individual listing.
All doors listed in Category B are eligible to bear the "S" (for Smoke & Draft Control assemblies) if a listed "Category H - Smoke & Draft Control Gasket" has been applied to the assembly. Please refer to Category H for individual gasket manufacturer's listings.
All doors in this category are identified by a label or marking bearing the wording, "Listed Fire Door", a time interval, a temperature rise rating, a serial number and the Warnock Hersey Certification Mark and "UBC-7-2-97/UL 10C".