SCM 1 - 3 Hour Steel Temperature Rise Doors PP Company: Stiles Custom Metal, Inc.

CATEGORY A DOORS-NO ADDITIONAL EDGE-SEALING REQUIRED 
 
Steel-Faced (12, 14, 16, 18, 20 gauge) Temperature Rise Swinging Flush Door for installation in up to 3 Hour locations. For use in listed (3-sided) 16 gauge welded steel frames meeting ANSI-A155.1/UL-63 or as per frame manufacturer's listing(s).
Limitations*:
Mortise or Cylindrical Latches with maximum 5" backset / Mortised Exit devices / Surface Mounted Vertical Rod fire exit devices / Rim Type fire exit devices / Concealed Vertical Rod exit devices (top rod only) / Deadbolts / Surface Bolts / Automatic Flush Bolts / Surface Mounted Closers / Concealed Closer Arms / Edge Guards / Surface Mounted Protection Plates / Viewer / Louvers / Surface Mounted or Mortised Door Bottoms / Doors may be fully clad on both sides with HPL, wood veneer, Stainless Steel or Bronze / Astragal optional on pairs / Temperature Rise – 250°F at 30 Minutes.
 
Vision Light Kits– Maximum 100 sq.in. using listed wire glass (in 90 minute only); Any listed temperature rise glass may be installed with 3/4" high stops. Pyrobel 60 not exceeding 87-5/8" in any direction or 3855 sq.in.; Pyrobel 90 not exceeding 35-1/4" in any direction or 1243 sq.in.
 
Configuration Maximum Size 90 Minute Rating* Maximum Size 3 Hour Rating*
Single Swing 4'3" wide x 9'0" high 4'0" wide x 8'0" high
Standard Pairs 8'6" wide x 9'0" high; 4'3" per leaf 8'0" wide x 8'0" high; 4'0" per leaf
Double Egress Pairs 8'6" wide x 9'0" high; 4'3" per leaf 8'0" wide x 8'0" high; 4'0" per leaf

*See manufacturer's installation instructions for additional information on Smoke and Draft Control, size restrictions and limitations.
Testing Standards: UBC-7-2-97/UL-10C (Positive Pressure). 
These doors are eligible for use in any "Category C - Standard" frame. These doors may also be installed in frames listed in "Category C - Proprietary" in the accordance with the frame manufacturer's individual listing.
All doors listed in Category A are eligible to bear the "S" (for Smoke & Draft Control assemblies) if a listed "Category H - Smoke & Draft Control Gasket" has been applied to the assembly. Please refer to Category H for individual gasket manufacturer's listings.
All doors in this category are identified by a label or marking bearing the wording, "Listed Fire Door", a time interval, a temperature rise rating, a serial number and the Warnock Hersey Certification Mark and "UBC-7-2-97/UL 10C".
Listing Report Certificate of Compliance Return to Search
Attributes
Certificate Date of ExpiryDecember 31, 2026
Certificate Date of Initial RegistrationMay 31, 2018
Certificate NumberWHI18–20392903
CriteriaNFPA 252 (1995)
CriteriaUL 10(c) (1998)
CriteriaUBC 7-2 (1997)
CriteriaUL 10(b) (1997)
CriteriaCAN / ULC S104 (1980) (R1985)
CriteriaUL 10(b) 2008 (R2009)
CriteriaUL 10(c) (2009)
CriteriaCAN / ULC S104 (2010)
CriteriaNFPA 252 (2012)
CSI Code08 11 00 Metal Doors and Frames
CSI Code08 11 13 Hollow Metal Doors and Frames
Fire Resistance20 Min w/Hose Stream PP Cat A Door
Fire Resistance60 Min PP Category A Door
Fire Resistance3 Hour PP Category A Door
Fire Resistance90 Min PP Category A Door
Fire Resistance45 Min PP Category A Door
Listing SectionCATEGORY A - DOORS - NO ADDITIONAL EDGE-SEALING SYSTEM REQUIRED
Spec ID32716
SwingSingle Swing
SwingStandard Pairs
SwingDouble Egress
Temperature Rise@ 30 Min = 250° F MAX Where Lites Do Not Exceed 100 IN2