SCM 1 - 3 Hour Steel Temperature Rise Doors PP
Company: Stiles Custom Metal, Inc.
CATEGORY A DOORS-NO ADDITIONAL EDGE-SEALING REQUIRED
Steel-Faced (12, 14, 16, 18, 20 gauge) Temperature Rise Swinging Flush Door for installation in up to 3 Hour locations. For use in listed (3-sided) 16 gauge welded steel frames meeting ANSI-A155.1/UL-63 or as per frame manufacturer's listing(s).
Limitations*:
Mortise or Cylindrical Latches with maximum 5" backset / Mortised Exit devices / Surface Mounted Vertical Rod fire exit devices / Rim Type fire exit devices / Concealed Vertical Rod exit devices (top rod only) / Deadbolts / Surface Bolts / Automatic Flush Bolts / Surface Mounted Closers / Concealed Closer Arms / Edge Guards / Surface Mounted Protection Plates / Viewer / Louvers / Surface Mounted or Mortised Door Bottoms / Doors may be fully clad on both sides with HPL, wood veneer, Stainless Steel or Bronze / Astragal optional on pairs / Temperature Rise – 250°F at 30 Minutes.
Vision Light Kits– Maximum 100 sq.in. using listed wire glass (in 90 minute only); Any listed temperature rise glass may be installed with 3/4" high stops. Pyrobel 60 not exceeding 87-5/8" in any direction or 3855 sq.in.; Pyrobel 90 not exceeding 35-1/4" in any direction or 1243 sq.in.
| Configuration |
Maximum Size 90 Minute Rating* |
Maximum Size 3 Hour Rating* |
| Single Swing |
4'3" wide x 9'0" high |
4'0" wide x 8'0" high |
| Standard Pairs |
8'6" wide x 9'0" high; 4'3" per leaf |
8'0" wide x 8'0" high; 4'0" per leaf |
| Double Egress Pairs |
8'6" wide x 9'0" high; 4'3" per leaf |
8'0" wide x 8'0" high; 4'0" per leaf |
*See manufacturer's installation instructions for additional information on Smoke and Draft Control, size restrictions and limitations.
Testing Standards: UBC-7-2-97/UL-10C (Positive Pressure).
These doors are eligible for use in any "Category C - Standard" frame. These doors may also be installed in frames listed in "Category C - Proprietary" in the accordance with the frame manufacturer's individual listing.
All doors listed in Category A are eligible to bear the "S" (for Smoke & Draft Control assemblies) if a listed "Category H - Smoke & Draft Control Gasket" has been applied to the assembly. Please refer to Category H for individual gasket manufacturer's listings.
All doors in this category are identified by a label or marking bearing the wording, "Listed Fire Door", a time interval, a temperature rise rating, a serial number and the Warnock Hersey Certification Mark and "UBC-7-2-97/UL 10C".