Maximum Size of Openings/Fire Ratings: |
Singles (20 gauge) (1-3/4") |
Single Point Lock or
Fire Exit Hardware |
3'8" wide x 7'2" high
3 Hour Maximum |
Singles (20 gauge) (1-3/4") |
Single Point Lock |
4'0" wide x 10'0" high
1-1/2 Hour Maximum |
Singles (20 gauge) (1-3/4") |
Fire Exit Hardware |
4'0" wide x 7'2" high
1-1/2 Hour Maximum |
Singles (18, 16 gauge) (1-3/4") |
Single Point Lock |
4'0" wide x 10'0" high
3 Hour Maximum |
Singles (18, 16, 14 gauge) (1-3/4") |
Fire Exit Hardware |
4'0" wide x 8'0" high
3 Hour Maximum |
Singles (18, 16, 14 gauge) (1-3/4") |
Fire Exit Hardware |
4'0" wide x 10'0" high
1-1/2 Hour Maximum |
Singles (14 gauge) (1-3/4") |
Single Point Lock or
Fire Exit Hardware |
4'0" wide x 8'0" high
3 Hour Maximum |
Pairs (20 gauge) (1-3/4") |
Single Point Lock |
8'0" wide x 7'2" high
1-1/2 Hour Maximum |
Pairs (18, 16, 14 gauge) (1-3/4") |
Single Point Lock or
Fire Exit Hardware |
8'0" wide x 10'0" high
1-1/2 Hour Maximum |
Pairs (18, 16, 14 gauge) (1-3/4") |
Single Point Lock or
Fire Exit Hardware |
8'0" wide x 8'0" high
3 Hour Maximum |
Pairs (14 gauge) (1-3/4") |
Single Point Lock or
Fire Exit Hardware |
8'0" wide x 8'0" high
3 Hour Maximum |
Pairs (18, 16, 14 gauge) (1-3/4") |
Single Point Lock or
Fire Exit Hardware
with Open-Back Strike |
8'0" wide x 7'2" high
1-1/2 Hour Maximum |
Double Egress Pairs
(18, 16, 14 gauge) (1-3/4") |
Fire Exit Hardware |
8'0" wide x 7'2" high
3 Hour Maximum |
Double Egress Pairs
(18, 16, 14 gauge) (1-3/4") |
Fire Exit Hardware |
8'0" wide x 9'0" high
1-1/2 Hour Maximum |
Dutch Singles
(18, 16 gauge) |
2 Single Point Locks |
4'0" wide x 7'2" high
3 Hour Maximum |