Intertek Directory of Building Products

AD Systems - Smoke & Draft Rated Sliding Doors Company: AD Systems

AD Systems' Smoke & Draft Rated Sliding Doors are sliding door systems that have been tested in accordance with UL 1784.
The doors are sliding barn-style doors.  The doors are hung in an aluminum frame and track system; there are two variants of sliding leaf, wood and aluminum framed.  A motorized head option is allowed for wood and aluminum sliding leafs. 
RATINGS ACHIEVED
The doors have been tested in accordance with UL 1784 and achieved results in accordance with the table below.  Results were achieved at a differential pressure of 0.10 in. water column (25 Pa).
Sliding Leaf Air Infiltration and Exfiltration at Ambient Temperature Air Infiltration and Exfiltration at Elevated Temperature
Wood 0.764 CFM/ft2 0.367 CFM/ft2
Aluminum 1.570 CFM/ft2 1.475 CFM/ft2
CFM/ft2: Cubic feet per minute per square foot of door area.

Dimensions of Test Assembly:
8'0" wide x 8'0" high

Sliding door configuration with 4'0" wide x 8'0" high sliding panel.
Sliding 4'0" wide x 8'0" high panel is with a fixed 4'-0" x 8'-0" sidelight panel on one side of door. 

Allowed optional configuration:  12' 0" wide x 8' -0" high with two fixed sidelight panels, one on each side of 4'-0" x 8'-0" sliding one direction door panel.

Certification of this product to the ratings above is permitted for sizes smaller or larger than the overall unit dimensions noted above.
Listing Report Return to Search
Attributes
CriteriaUL 1784 (2009)
CriteriaUL 1784 (2015)
CSI Code08 10 00 Doors and Frames
Listing SectionDOORS
Spec ID33018
Design Documents
No Results
Public Documents
No Results