Intertek Directory of Building Products

Envolution Insulated Metal Panels Company: Envolution

Envolution Wall Panel, Envolution EVR Standing Seam Panel & Envolution EVR Ribbed Roof Panel (Roof) Insulated Metal Panels

Envolution Wall Panel, Envolution EVR Standing Seam Panel, and Envolution EVR Ribbed Roof Panels are composite panels made of a polyurethane foam core which is foamed in place between the roll formed steel faces. 

Envolution Wall Panel, Envolution EVR Standing Seam Panels min. panel thickness is 2 in.  Envolution EVR Ribbed Roof Panels min. panel thickness is 1-1/2 in.  Max. panel thickness is 6 in. for all panels.  Panel width may be 12'' to 44.5''.  Panel face thickness may be 26 gauge to 22 gauge.  Panel face profile may be any of the published standard profiles.  Envolution Wall Panels may be installed in the vertical or horizontal orientation.  Envolution EVR Standing Seam Panels are installed as roof panels.

One edge of the panel is formed with a unique “male”-connection profile, while the other edge is formed with the corresponding “female”-connection profile.  The ends of the panel are cut straight and square.  Panels are not fully encapsulated by the metal skin—the foam core is exposed around all edges.  The panels are installed thru interlocking of adjacent panels, and flashing installed over the panel ends providing a continous steel skin weather barrier and non combustible steel face protecting the polyurethane core.  The panel core is a two-component (Part A and Part B) polyurethane foam that is mixed and injected between the steel skins. 

RATINGS
 

PRODUCT STANDARD RATING
Envolution Wall, Envolution EVR Standing Seam, and Envolution EVR Ribbed Roof Panel Assembly ASTM E84 (2010b) Flame Spread: <25
Smoke Developed: <450
Envolution Wall, Envolution EVR Standing Seam, and Envolution EVR Ribbed Roof Panel Foam Core ASTM E84 (2010b) Flame Spread: <25
Smoke Developed: <450
Envolution Wall, Envolution EVR Standing Seam, and Envolution EVR Ribbed Roof Panel Assembly with Gypsum Wall Board ASTM E119 (2010e) 1 Hour Non Load Bearing Fire Rating
Envolution Wall, Envolution EVR Standing Seam, and Envolution EVR Ribbed Roof Panel Assembly CAN/ULC S101 (2007) Meets 15 Minute Stay in Place Requirements
(See Design No. MSN/CWP 15-01)
Envolution Wall, Envolution EVR Standing Seam, and Envolution EVR Ribbed Roof Panel Assembly with Gypsum Wall Board CAN/ULC S101 (2007) 1 Hour Non Load Bearing Fire Rating
Envolution Wall, Envolution EVR Standing Seam, and Envolution EVR Ribbed Roof Panel Assembly CAN/ULC S102 (2010) Flame Spread: 0
Smoke Developed: 17
Fuel Contribution Value: 0 (average)
Envolution Wall, Envolution EVR Standing Seam, and Envolution EVR Ribbed Roof Panel Foam Core CAN/ULC S102 (2010) Flame Spread: 10
Smoke Developed: 40
Fuel Contribution Value: 0 (average)
Envolution EVR Standing Seam Panel & Envolution EVR Ribbed Roof Panel Assembly CAN/ULC S126-M86 (R2000) Flame Spread: Pass
Smoke Developed: Pass
Envolution Wall Panel & Envolution EVR Ribbed Roof Panel Assembly CAN/ULS S134 (1992) Flame Spread: < 5m
Heat Flux: <35 KW/m2
Meets NBC 2005 Section 3.1.5.5
(See Design No. MSN/CWP 30-03)
Envolution Wall Panel Assembly CAN/ULC S138 (2006) Meets Requirements
Envolution Wall, Envolution EVR Standing Seam, and Envolution EVR Ribbed Roof Panel Assembly NFPA 259 (2008) 11150.8 Btu/lb Average
Envolution Wall & Envolution EVR Ribbed Roof Panel Assembly NFPA 285 (2006) Meets Requirements
(See Design No. ENV/CWP 30-01)
Envolution Wall, Envolution EVR Standing Seam, and Envolution EVR Ribbed Roof Panel Assembly NFPA 286 (2006) Meets IBC 2009 Section 803.1.2.1
15 Minute Duration
Envolution EVR Standing Seam & Envolution EVR Ribbed Roof Panel Assembly ASTM E 108 (2011)
and
CAN/ULC S 107 (2010)
Class A Spread of Flame – Pass†
Class A Intermittent Flame - Pass†
Class A Burning Brand - Pass†
(†Unlimited Roof Slope)

 

Listing Report Return to Search
Attributes
CriteriaCAN / ULC S107 (1987)
CriteriaCAN / ULC S101 (2007)
CriteriaCAN / ULC S126-M86 (R2000)
CriteriaCAN / ULC S134-92 (R1998)
CriteriaNFPA 286 (2006)
CriteriaNFPA 259 (2008)
CriteriaASTM E84 (2012)
CriteriaASTM E84 (2011c)
CriteriaASTM E84 (2011b)
CriteriaNFPA 285 (2012)
CriteriaASTM E119 (2012a)
CriteriaCAN / ULC S138 (2006)
CriteriaNFPA 285 (2006)
CriteriaASTM E84 (2010b)
CriteriaASTM E108 (2010a)
CriteriaCAN / ULC S102 (2010)
CriteriaASTM E84 (2011a)
CSI Code07 40 00 Roofing and Siding Panels
CSI Code07 42 43 Composite Wall Panels
Listing SectionBUILDING PANELS
Spec ID34237
Design Documents
Public Documents
No Results