Malarkey AC/N-38 Combustible or Non-Combustible Deck Slope 1:12 Company: Malarkey Roofing Products

CLASS A
 
Deck: Combustible or Non-Combustible
Slope: 1:12 (AC/N-38) 
  1. Optional Insulations: Manufacturer specified, certified insulations.
     
  2. 1-Ply 610 Paragon Ultra SA Base or 1-Ply 610 Paragon Ultra SA HT Base, self adhesive base sheet or 1-Ply 410 OmniSeal self adhesivebase sheet or 1-PLY 420 Omni Seal self adhesive base sheet OR 1-Ply 620 Paragon Ultra TG Base, mechanically fastened.

    If this system configuration includes a 620 Paragon Ultra TG Base ply sheet (Item 3 below), then the following base options are allowed:

    One ply of any of the following base sheets 501 Paragon Mod Base, 503, 515 Panobase, 602 Paragon Ultra Base, 603 Paragon Super Base, 605 Paragon Plus Base, 606 Paragon Duo Base,  401 Artic Seal self adhesive base sheet, or ply sheets 500 PanoPly 4, 506 PanoPly 6, mechanically fastened.

    When installing this system over a listed gypsum coverboard (minimum 1/4" thick) or directly to a non-combustible deck, this ply (Item 2) becomes optional.
  3. Optional: 1-Ply 620 Paragon Ultra TG Base, mechanically fastened or torch applied.
     
  4. 1-Ply 630 Paragon Ultra TG Cap, torch applied or Malarkey 626G Paragon® Rcap™ hot mopped or torch applied.
Note: The component materials of each system must be applied in the order in which they are listed above.
 
For additional product information, visit Malarkey's website at www.malarkeyroofing.com.

Evaluated to the following...
The roof covering systems in this section have been evaluated for external fire resistance Classifications A, B, C as outlined by the following test methods:
  • ASTM-E108 - American Society for Testing & Materials 'Standard Methods of Fire Test of Roof Covering'
  • FM-4470, Section 5.1.A - Factory Mutual 'Standard Method of Test for Fire Resistance of Roof Covering Materials'
  • NFPA-256 - National Fire Protection 'Standard Method of Fire Tests of Roof Covering'
  • UBC-15-2-94 - Uniform Building Code 'Test Standard for Determining the Fire Retardancy of Roof Covering Materials'
  • CAN/ULC-S107 - Underwriters' Laboratories of Canada 'Standard Method of Tests for Fire Resistance of Roof Covering Materials'
  • UL-790 - Underwriters' Laboratories Inc. 'Tests for Fire Resistance of Roof Covering Materials'
Each system listing identifies the deck substrate as either non-combustible or combustible. Systems evaluated for combustible decks will provide the same ratings when applied over non-combustible decks. Unless otherwise noted in individual listings, combustible decks shall be sheathed with a minimum 15/32" veneer plywood or minimum 7/16" non-veneer APA rated sheathing panel (oriented strand board panels, structural particleboard panels, composite panels or wafer-board panels) or 3/4" thick solid wood sheathing boards. The component materials of each system must be applied in the order in which they are listed. All components of the system must be listed for external fire exposure by an agency acceptable to the AHJ.

Some Roof Covering Systems have been evaluated for other performance characteristics, in addition to external fire exposure. Where applicable, such additional performance characteristics are noted within the specific listing.

In all cases, manufacturer's instructions should be consulted for installation procedures and details not covered by these listings.

Listed Materials are identified by a label or marking bearing the wording, "Listed Roofing Component", a reference number or code and the WHI Certification Mark.
Listing Report Return to Search
Attributes
CriteriaCAN / ULC S107 (1987)
CriteriaUL 790 (2004)
CriteriaASTM E108 (2010a)
CriteriaASTM E108 (2017)
CSI Code07 52 00 Modified Bituminous Membrane Roofing
Listing SectionROOF COVERING SYSTEMS
Roofing: Deck TypeCombustible
Roofing: Deck TypeNon-Combustible
Roofing: Fire RatingClass A
Roofing: Maximum Slope1:12