Construction Specialties 90 Minute Fire Rated Acrovyn® Door
Product Description:
Listed GP Mineral Core, Swinging flush door with Acrovyn faces for installation in up to 90 minute fire rated locations. For use in Category A or Category B applications depending on edge construction; for Category B applications, a field-applied edge seal system is required.
For use in listed Category C - Standard frames, (3 -sided 16-gauge welded steel frames meeting ANSI A155.1/ UL 63 or as per frame manufacturer's listings).
MAXIMUM SIZES
Singles 4'-0 wide x 9'-0 high
Pairs (Standard) 8'-0 wide x 9'-0 high
Pairs (Double Egress pairs) 8'-0 wide x 8'-0 high
Minimum Thickness: 1-3/4"
Note:
-
Minimum 2-point latching on pairs. See manufacturing information for stile and rail requirements.
Limitations:
Cylindrical Latches with maximum 5" backset / Mortised Latchsets / Surface Mounted Vertical Rod fire exit device / Concealed Vertical Rod fire exit device with metal edges / Rim Type fire exit device / Less Bottom Rod fire exit device / Deadbolts / Surface Bolts or Automatic Flush Bolts / Surface Mounted or Mortised Door Bottoms / Vision Lite Kit - Maximum 100 sq. in. / Surface Mounted or Concealed Closers / Electric Raceways / Surface Mounted Protection Plates / Viewer.
TESTING STANDARDS
UL 10c, NFPA 252, and CAN / ULC S104.