Intertek Directory of Building Products

VT 20 Minute Glazed Pair SCL Core Full Light Fire Door Assembly Company: VT Industries, Inc.

SCL core fire door pair assembly with full light glazing. For installation in up to 20-minute locations without hose stream. For use in listed (3-sided) 16 gauge welded steel frames meeting UL-63 or as per frame manufacturer's listing(s).

Limitations*
Minimum 3-point Latching required
Cylindrical Latches with maximum 2-3/4" Backset/Surface-Mounted Vertical Rod Fire Exit Devices/Surface Mounted Bolts/Deadbolts/Surface-Mounted Closers/Surface-Mounted Protection Plates/Surface-Mounted Door Bottoms.
Maximum Sizes*
Single Swing       Not Applicable
Standard Pairs     8'-0" x 8'-0" (Individual Leaf Size Not To Exceed 4'0" x 8'0")

Double Egress Pairs:  Not Allowed

Clear View  (Glazing to be centered in the door)    Listed & Labeled ¼” thick ceramic glass 37” wide x 79-3/4” high (2,950.75 sq.in.) 

*See manufacturer's installation instructions for additional information on Smoke and Draft Control, size restrictions, and limitations.
Listing Report Return to Search
Attributes
CriteriaUL 10(c) (2016)
CriteriaNFPA 252 (2017)
CSI Code08 10 00 Doors and Frames
Fire Resistance20 Min w/out Hose Stream PP Cat A Door
Listing SectionCATEGORY A - DOORS - NO ADDITIONAL EDGE-SEALING SYSTEM REQUIRED
Spec ID35060
SwingStandard Pairs
Design Documents
No Results