VT 20 Minute Glazed Pair SCL Core Full Light Fire Door Assembly
Company: VT Industries, Inc.
SCL core fire door pair assembly with full light glazing. For installation in up to 20-minute locations without hose stream. For use in listed (3-sided) 16 gauge welded steel frames meeting UL-63 or as per frame manufacturer's listing(s).
Limitations*
Minimum 3-point Latching required
Cylindrical Latches with maximum 2-3/4" Backset/Surface-Mounted Vertical Rod Fire Exit Devices/Surface Mounted Bolts/Deadbolts/Surface-Mounted Closers/Surface-Mounted Protection Plates/Surface-Mounted Door Bottoms.
Maximum Sizes*
Single Swing Not Applicable
Standard Pairs 8'-0" x 8'-0" (Individual Leaf Size Not To Exceed 4'0" x 8'0")
Double Egress Pairs: Not Allowed
Clear View (Glazing to be centered in the door) Listed & Labeled ¼” thick ceramic glass 37” wide x 79-3/4” high (2,950.75 sq.in.)
*See manufacturer's installation instructions for additional information on Smoke and Draft Control, size restrictions, and limitations.