FRCT - FX Lumber Guard and FX Lumber Guard XT Company: Fire Retardant Coatings of Texas, LLC - (Fort Worth, TX) Code Compliance Research Reports: CCRR-1044

FX Lumber Guard and FX Lumber Guard XT are clear fire-retardant penetrants intended to reduce the flammability of wood and wood products by penetrating the wood with fire retardants and by creating a barrier when exposed to flames. Once the penetrant is dry, the solids left behind become the barrier layer. Application is in one coat, to be applied at the designated rate of 300-350 square feet per gallon. The product can be field-applied or factory-applied by the approved applicators.

FLAME SPREAD RATINGS –
DIMMENSIONAL LUMBER (including SPF, SYP, Douglas Fir, Hemlock Fir)
Test Standard Flame Spread Smoke Development
ASTM E84 < 25 < 200
 
Test Standard Maximum Flame Front
ASTM E2768 < 10.5 ft

FLAME SPREAD RATINGS –
PLYWOOD (including SYP, SPF, Douglas Fir)
Test Standard Flame Spread Smoke Development
ASTM E84 < 25 < 200
 
Test Standard Maximum Flame Front
ASTM E2768 < 10.5 ft

FLAME SPREAD RATINGS –
OSB
Test Standard Flame Spread Smoke Development
ASTM E84 < 25 < 200
 
Test Standard Maximum Flame Front
ASTM E2768 < 10.5 ft

CODE COMPLIANCE RESEARCH REPORT
EVALUATION METHOD BUILDING CODE CCRR NUMBER
ICC-ES AC363  2021, 2018, 2015  IBC
 2021, 2018, 2015 IRC
 2021, 2018, 2015 IFC
 2021, 2018, 2015 IEBC
CCRR-1044

Approved Factory Applicators
Manufacturer Location
Global Fireproof Solutions, Inc. Groveland, FL
Adel, GA
U.S. Lumber Group, LLC Heath, OH
AccuTreated Deer Park, NY
Chicago Flameproof Montgomery, IL 
Fort Worth, TX
Listing Report Return to Search
Attributes
Code ReportsYes
CriteriaASTM E2768-11 (R2018)
CriteriaICC-ES AC363 (2007)
CriteriaASTM E84 (2018b)
CSI Code06 05 73 Wood Treatment
CSI Code09 96 43 Fire-Retardant Coatings
Listing SectionBUILDING MATERIALS WITH SURFACE BURNING CHARACTERISTICS
Spec ID35257