Intertek Directory of Building Products

Jotul Models GF 500 DV and GF 500 DV MV Direct Vent Gas Fireplace Heater Company: Jøtul North America, Inc.

PRODUCT DESCRIPTION
Product Direct Vent Gas Fireplace
Brand Name Jotul
Description The models Jotul GF500 DV and GF500 DV MV direct vent gas fireplace heaters are freestanding appliances. They are equipped and operated with a millivolt ignition system. The unit front and sides contain glass panels for viewing the flame and simulated wood logs.
The models GF500 DV and GF500 DV MV Direct Vent Gas Room Heaters are constructed of carbon steel firebox, with a cast iron outer shell. Both models are free-standing stoves that use 4-inch by 6 5/8-inch co-axial venting. They are approved for use with snorkel vent components.
Models GF500 DV and GF500 DV MV
Model Similarity The models GF500DV and GF500DV MV are identical with the only difference being that the GF500DV MV uses a pilot on demand control valve that turns off the pilot burner after 7 days of uninterrupted use.
Ratings 120V, 1.5A, 60 Hz, 50W (Blower)

APPLIANCE RATINGS
  NATURAL GAS PROPANE
Model GF500 DV and GF500 DV MV
Orifice Size (0-2000 ft) (f/r) 2.25mm/#47 1.40mm/1.20mm
Orifice Size (2000-4500 ft) (f/r) #44/#48 1.35mm/1.15mm
Normal Input Rate (Btu/hr)(0-2000-ft) 40,000 39,500
Normal Input Rate (Btu/hr)(2000-4500-ft) 38,000 37,900
Manifold Pressure at Normal Input Rate (in.wc/kPa) 3.8/0.95 11.0/2.74
Minimum Input Rate (Btu/hr) 12,800 14,000
Manifold Pressure at Minimum Input Rate (in.wc/kPa) 1.2/0.30 2.9/0.72
Minimum Inlet Pressure (in.wc/kPa) 5.0/1.24 12.0/2.99

VENTING INFORMATION
Any combination of rise and run may be used if it is within the boundaries indicated below. The total vent length shall not exceed 35 feet. Refer to the Owner’s Manual for more details on the permissible venting configurations.
VENTING
Vent Type Coaxial vent
Vent Size 4” x 6 5/8”
Max. Vertical Length 35-feet
Min. Vertical Length 6-feet
Max. Horizontal Length 27-feet
Min. Horizontal Length 12-in
Max. Horizontal Length at Min. Vertical Length 5-feet
Min. Vertical Length at Max. Horizontal Length 8-feet
Max. Number of Elbows 2-90°
 
VENT MANUFACTURERS
DuraVent GS
American Metal Products AmeriVent
Security Chimneys International, Ltd. Secure Vent
Selkirk Metalbestos Direct Temp
Metal-Fab, Inc. Sure-Seal Direct Vent
Industrial Chimney Corp. ExcelDirect
Bernard Dalsin Mfg. Pro Form
Olympia Chimney Supply, Inc. Ventis Direct Vent

CLEARANCES TO COMBUSTIBLE CONSTRUCTION
CLEARANCES
Rear (in/mm) 1.5/38
Sidewall (in/mm) (right) 2/51
Corner (in/mm) 2/51
Ceiling (in/mm) (from unit top) 20.25/514
 
VENTING SYSTEM CLEARANCES
Top of Horizontal Vent (in/mm) 2/51
Sides and Bottom of Horizontal Vent (in/mm) 1/25
Side of Vertical Vent (in/mm) 1/25
 
MINIMUM ALCOVE DIMENSIONS
Width (in/mm) 32.5/826
Height (in/mm) (standard legs) 50.25/1276
Height (in/mm) (short legs) 48/1219
Depth (in/mm) 24/610
Listing Report Return to Search
Attributes
CriteriaCSA 2.17 Ed.4 (2017) (R2022)
CriteriaANSI Z21.88 / CSA 2.33 (2019) (R2024)
CSI Code10 30 00 Fireplaces and Stoves
Fuel TypePropane
Fuel TypeNatural Gas
Listing SectionVENTED GAS FIREPLACE HEATERS
Spec ID36124
Design Documents
No Results
Public Documents
No Results