Intertek Directory of Building Products

SAFTI FIRST SuperLite II-XLB 120 Fire Rated Wall Assembly Company: SAFTI FIRST

PRODUCT DESCRIPTION

The SAFTI FIRST SuperLite II-XLB 120 2-1/2 in. glass panels are composed of alternating tempered glass and intumescing gel layers to provide a transparent, yet fire protective barrier. The gel remains inactive and transparent until exposed to heat at which point it transforms into an opaque protective barrier.

Options:
Layers: Patterns, Integral Opaque, Obscure Surface Finish, Applied Films, or Tints. 

IGU's
IGU units would consist of a minimum 8mm gap, steel, aluminum, glass or listed current TPS spacers with tempered or laminate glazing panes with a Low-E outboard. 

RATINGS
 
SF/GG 120-01 & SF/GG 120-04
ASTM E119 - CAN/ULC S101 - UL 263 - 2 hrs
Max Individual Panel Dimensions
Maximum Allowable Panel Area 8040 sq. in.
Maximum Allowable Panel Width 134 in.
Maximum Allowable Panel Height 134 in.
Minimum Thickness 2-1/2 in.


Manufacturer's Instructions

Listed maximum sizes of glazing are based on sizes tested and may exceed those allowed by local codes. Dependent on the end use installation, local codes may require that additional criteria be met to address considerations such as radiant heat hazards and impact safety. Under such circumstances, the prior approval of the Authority Having Jurisdiction must be obtained unless conformance to relevant additional requirements is indicated within the individual testing. All glazing is identified by an etched mark or label bearing the ETL Certification Mark.
 
Listing Report Certificate of Compliance Return to Search
Attributes
Certificate Date of ExpiryDecember 31, 2026
Certificate Date of Initial RegistrationAugust 12, 2022
Certificate NumberWHI22-20840018
CriteriaUL 263 (2011)
CriteriaCAN / ULC S101 (2014)
CriteriaASTM E119 (2015)
CriteriaUL 263: 2011 Ed. 14 (R2015)
CriteriaASTM E119 (2019)
CriteriaASTM E119 (2020)
CSI Code08 80 00 Glazing
Listing SectionGLAZING/GLASS