Quik-Felt is a 7-mil thick mechanically attached synthetic roofing underlayment composed of a polypropylene woven scrim laminated with a polypropylene non-woven layer on the exposed side and a polyolefin coating layer on the sheathing side. The underlayment is available in custom colours and supplied in rolls of various sizes.
Deck Guard is a 6-mil thick mechanically attached synthetic roofing underlayment composed of a polypropylene woven scrim laminated with a polypropylene non-woven layer on the exposed side and a polyolefin coating layer on the sheathing side. The underlayment is available in custom colours and supplied in rolls of various sizes.
PHYSICAL RATINGS
| PRODUCT |
TEST METHOD |
TEST PROCEDURE |
RESULTS |
| Quik-Felt and Deck Guard Synthetic Roofing Underlayments |
ASTM D226 |
Unroll-ability |
Meets Type II |
| Breaking Strength |
Meets Type II |
| Pliability |
Meets Type II |
| Loss on Heating |
Meets Type II |
| CSA A123.3 |
Unroll-ability |
Meets Type 3 |
| Breaking Strength |
Meets Type 3 |
| Pliability |
Meets Type 3 |
| Loss on Heating |
Meets Type 3 |
| Liquid Water Transmission |
Meets Type 3 |
| ASTM D4869 |
Unroll-ability |
Meets Type IV |
| Breaking Strength |
Meets Type IV |
| Pliability |
Meets Type IV |
| Loss on Heating |
Meets Type IV |
| Liquid Water Transmission |
Meets Type IV |
| Tear Strength |
Meets Type IV |
| Dimensional Stability |
Meets Type IV |
| CAN/CSA A220 |
All test procedures applicable to underlayments for use in areas having 3500 degree days or less below 18 degrees |
Meets Standard Requirements |
FIRE CLASSIFICATION
Class A Assemblies
| Assembly No. |
E108-RFU-37155 |
Slope:
Deck Type:
Details: |
2:12 or greater
Combustible
- Minimum nominal 15/32” thick Code Compliant exterior grade plywood
- A single layer of Quik-Felt or Deck Guard roofing underlayment mechanically fastened to the plywood sheathing every 12 inch oc in the field and on the perimeter using plastic cap nails
- Asphalt shingles Listed per ASTM D3462 with a minimum weight of 190 pounds per 100 square feet installed per manufacturer’s installation instruction
|
CODE COMPLIANCE RESEARCH REPORT
| Evaluation Method |
Building Code |
CCRR Number |
ICC-ES AC188
ASTM D8257
ASTM E108
UL 790 |
2024, 2021, and 2018, IBC
2024, 2021, and 2018 IRC
2024 IWUIC
2026, 2023 FBC
2025, 2022 CBC
2025, 2022 CRC
2025 CWUIC
2023 LABC
2023 LARC |
CCRR-1048 |