Creative Composites 45 Minute NP/PP Wood Composite Lead Lined Door Company: Creative Composites, Ltd.

FIRE RESISTANT PRODUCTS & COMPONENTS

CATEGORY A DOORS - NO ADDITIONAL EDGE-SEALING SYSTEM REQUIRED
Category "A" Wood Composite Core, swinging door for use in 20 through 45 minute positive pressure assemblies (also eligible for use in neutral pressure assemblies). 

CATEGORY B DOORS - ADDITIONAL EDGE-SEALING SYSTEM REQUIRED
Category "B" Wood Composite Core, swinging door for use in 20 through 45 minute positive pressure assemblies (also eligible for use in neutral pressure assemblies).  A surface applied Category G intumescent edge seal system is required.

PRODUCT COVERED
Creative Composites 20-45 Minute Wood Composite Lead Lined Fire Door

PRODUCT DESCRIPTION
Hardware Limitations:  Cylindrical / Cylindrical with Deadbolt / Mortise / Card Reader / Surface-Mounted Vertical Rod Fire Exit Devices / Rim-Type Surface Mounted Fire Exit Devices / Surface Bolts or Mortised Flush Bolts / Surface Mounted or Concealed Door Bottoms / Surface Mounted or Concealed Closers or Overhead Stops / Viewer / Vision Kit - Max. 256sq. in. / Raceway / EPT / Plant-Ons / Protection Plates 

Configuration                   Maximum Size
Single                                4'0" wide x 8'0" high
 
The product noted above has been tested and qualified per UL 10C, NFPA 252, and CAN/ULC S104 for a 45 Minute Positive Pressure Fire Rating.  
These doors are eligible for use in any "Category C - Standard" frame. These doors may also be installed in frames listed in "Category C - Proprietary" in the accordance with the frame manufacturer's individual listing.
The door noted above is eligible to bear the "S" (for Smoke & Draft Control assemblies) if a listed "Category H - Smoke & Draft Control Gasket" has been applied to the assembly. Please refer to Category H for individual gasket manufacturer's listings.
Listing Report Return to Search
Attributes
CriteriaCAN / ULC S104 (2015) (R2020)
CriteriaNFPA 252 (2017)
CriteriaUL 10(b) (2008) (R2020)
CriteriaUL 10(c) (2016) Ed. 3 (R:27 May 2021)
CSI Code08 14 00 Wood Doors
Fire Resistance20 Min w/Hose Positive Pressure
Fire Resistance45 Min Positive Pressure
Listing SectionCATEGORY B - DOORS - ADDITIONAL EDGE-SEALING SYSTEM REQUIRED
Listing SectionCATEGORY A - DOORS - NO ADDITIONAL EDGE-SEALING SYSTEM REQUIRED
Smoke and Draft ControlRating Require a Listed Gasket
Spec ID37271
SwingSingle Swing
SwingTransom
Temperature Rise@ 30 Min = 250° F MAX Where Lites Do Not Exceed 100 IN2