Intertek Directory of Building Products

Jotul GI 535 DV IPI Vented Gas Fireplace Heater Company: Jøtul North America, Inc.

PRODUCT DESCRIPTION
Product Direct Vent Gas Fireplace Insert
Brand Name Jotul
Description The model Jotul GI535 DV IPI direct vent gas fireplace heater is designed to inserted into existing solid-fuel fireplaces. It is equipped and operated with an (Intermittent / Pilot on Demand) ignition system. The unit front and sides contain glass panels for viewing the flame and simulated wood logs.
Models GI535 DV IPI
Model Similarity None
Ratings 120V, 2.1A, 60 Hz

APPLIANCE RATINGS
  NATURAL GAS PROPANE
Model GI535 DV IPI
Orifice Size (0-2000 ft) (f/r) 1.95mm/#48 0.046 in/#56
Orifice Size (2000-4500 ft) (f/r) #48/#49 #56/#57
Normal Input Rate (Btu/hr)(0-2000-ft) 32,000 31,500
Normal Input Rate (Btu/hr)(2000-4500-ft) 31,000 30,500
Manifold Pressure at Normal Input Rate (in.wc/kPa) 3.5/0.87 10.0/2.49
Minimum Input Rate (Btu/hr) 11,500 11,000
Manifold Pressure at Minimum Input Rate (in.wc/kPa) 1.6/0.39 6.4/1.59
Minimum Inlet Pressure (in.wc/kPa) 5.0/1.24 12.0/2.99

VENTING INFORMATION
Any combination of rise and run may be used if it is within the boundaries indicated below. The total vent length shall not exceed 35 feet. Refer to the Owner’s Manual for more details on the permissible venting configurations.
VENTING
Vent Type Colinear vent
Vent Size 3” x 3”
Max. Vertical Length 35-feet
Min. Vertical Length 10-feet
 
VENT MANUFACTURERS
DuraVent  
American Metal Products  
Metal-Fab, Inc.  
Industrial Chimney Corporation  
Selkirk-Metalbestos  
Security Chimneys  

CLEARANCES TO COMBUSTIBLE CONSTRUCTION
CLEARANCES
Sidewall (in/mm) (from unit center) 22.375/517
Hearth Protection Width (in/mm) (from fireplace opening) 3.125/80
Hearth Protection Depth (in/mm) (unit flush) 12/305
Hearth Protection Depth (in/mm) (unit raised 6”) 0
Side Trim (in/mm) (up to 6” thick, from fireplace center) 17.875/454
Top Trim (in/mm) 36.5/927
Mantle (in/mm) (12” deep) 39.25/997
Listing Report Return to Search
Attributes
CriteriaCSA 2.17 Ed.4 (2017) (R2022)
CriteriaANSI Z21.88 / CSA 2.33 (2019) (R2024)
CSI Code10 30 00 Fireplaces and Stoves
Fuel TypePropane
Fuel TypeNatural Gas
Listing SectionVENTED GAS FIREPLACE HEATERS
Spec ID37395
Design Documents
No Results
Public Documents
No Results