Kooltherm
® insulation boards are phenolic foam core insulation boards used as non-structural thermal insulation in ceiling, floor assemblies, and door cavities.
Kooltherm
® K15, K8, K7 and K12 insulation boards have composite foil facers on both surfaces, have a nominal core density of 2.0 pcf and are supplied in thicknesses ranging from 25mm to 100mm.
Kooltherm
® K10 insulation boards have a glass fiber tissue-based facing on the back surface and a composite foil facer on the exterior surface, have a nominal core density of 2.0 pcf and are supplied in thicknesses ranging from 25mm to 100mm. .
Kooltherm
® K20, K9, K5 and K3 insulation boards have a glass fiber tissue-based facing on both surfaces, have a nominal core density of 2.0 pcf and are supplied in thicknesses ranging from 25mm to 100mm.
Kooltherm
®K122 and K108 RF insulation boards have a foil facing on both sides.
Kooltherm
® K110 insulation boards have a glass ifber tissue-based facing on the back surface and a foil facer on the exterior surface.
Kooltherm
® K120 insulation boards have a glass fiber tissue-based facing on both surfaces.
The Kooltherm
® K-100 series insulation boards have a nominal core density of 2.4 pcf and are supplied in thicknesses ranging from 40mm to 100mm.
FLAME SPREAD RATINGS
Test Standard |
Flame Spread |
Smoke Development |
UL 723 (E84)
(K20, K9, K5, K3)
(K10 with glass fiber tissue facing exposed) |
≤ 25 |
≤ 450 |
UL 723 (E84)
(K15, K8, K7, K12)
(K10 with foil facing exposed) |
≤ 25 |
≤ 450 |
UL 723 (E84)
K110, K120, K122, K108 RF |
≤ 25 |
≤ 450 |
FIRE RATINGS
Test Standard |
Rating |
Design Number |
NFPA 285 |
Meets requirements |
KIL/BI 30-02 |
CODE COMPLIANCE RESEARCH REPORT
Evaluation Method |
Building Code |
Report No. |
ICC-ES AC12 |
2024, 2021, 2018 IBC
2024, 2021, 2018 IRC
2024, 2021, 2018 IECC |
CCRR-1066 |