Intertek Directory of Building Products

Kingspan - Kooltherm® Phenolic Insulation Boards Company: Kingspan Insulation LLC Code Compliance Research Reports: CCRR-1066

Kooltherm® insulation boards are phenolic foam core insulation boards used as non-structural thermal insulation in ceiling, floor assemblies, and door cavities.

Kooltherm® K15, K8, K7 and K12 insulation boards have composite foil facers on both surfaces, have a nominal core density of 2.0 pcf and are supplied in thicknesses ranging from 25mm to 100mm.  
 
Kooltherm® K10 insulation boards have a glass fiber tissue-based facing on the back surface and a composite foil facer on the exterior surface, have a nominal core density of 2.0 pcf and are supplied in thicknesses ranging from 25mm to 100mm.  .
 
Kooltherm® K20, K9, K5 and K3 insulation boards have a glass fiber tissue-based facing on both surfaces, have a nominal core density of 2.0 pcf and are supplied in thicknesses ranging from 25mm to 100mm.    

Kooltherm®K122 and K108 RF insulation boards have a foil facing on both sides.

Kooltherm®  K110 insulation boards have a glass ifber tissue-based facing on the back surface and a foil facer on the exterior surface.
 
Kooltherm® K120 insulation boards have a glass fiber tissue-based facing on both surfaces.

The Kooltherm® K-100 series insulation boards have a nominal core density of 2.4 pcf and are supplied in thicknesses ranging from 40mm to 100mm.

 
FLAME SPREAD RATINGS
Test Standard  Flame Spread Smoke Development
UL 723 (E84)
(K20, K9, K5, K3)
(K10 with glass fiber tissue facing exposed)
≤ 25 ≤ 450
UL 723 (E84)
(K15, K8, K7, K12)
(K10 with foil facing exposed)
≤ 25 ≤ 450
UL 723 (E84)
K110, K120, K122, K108 RF
≤ 25 ≤ 450


FIRE RATINGS
Test Standard Rating Design Number
NFPA 285 Meets requirements KIL/BI 30-02


CODE COMPLIANCE RESEARCH REPORT
Evaluation Method Building Code Report No.
ICC-ES AC12 2024, 2021, 2018 IBC
2024, 2021, 2018 IRC
2024, 2021, 2018 IECC
CCRR-1066

 
Listing Report Return to Search
Attributes
CriteriaICC-ES AC12 (2015) rev. 2016
CriteriaUL 723 (2018) Ed.11
CriteriaASTM E84 (2021a)
CriteriaNFPA 285 (2023)
CSI Code07 21 13 Board Insulation
Listing SectionTHERMAL INSULATION BOARDS
Spec ID39633
Design Documents
Code Compliance Research Reports
Public Documents
No Results