James Hardie HardiePanel® Vertical Siding smooth and textured (HZ5 and HZ10); HardieSoffit® smooth and textured, vented and non-vented (HZ5 and HZ10); Prevail® Soffit, smooth and textured, vented and non-vented; CemPanel® Vertical Siding, and Prevail®
Panel are fiber cement panel sidings.
| Product |
Dimensions |
Weight |
| HardiePanel® Vertical Siding smooth and textured (HZ5 and HZ10) |
Width: 48 in.
Lengths: 96 in., 108 in., and 120 in. |
Width: 16 in.
Length: 96 in., 120 in., and 144 in. |
2.3 lb/ft2 |
| Thickness: 0.312 in. |
| HardieSoffit® smooth and textured, vented and non-vented (HZ5 and HZ10) |
Widths: 12 in., 16 in., 24 in, and 48 in.
Lengths: 96 in. and 144 in.
Thickness: 0.25 in. |
1.9 lb/ft2 |
| Prevail® Soffit, smooth and textured, vented and non-vented |
Widths: 12 in., 16 in., 24 in, and 48 in.
Lengths: 96 in. and 144 in.
Thickness: 0.25 in. |
1.9 lb/ft2 |
| CemPanel® Vertical Siding |
Width: 48 in.
Length: 96 in.
Thickness: 0.312 in. |
2.3 lb/ft2 |
| Prevail® Panel Siding |
Width: 48 in.
Lengths: 96 in., 108 in., and 120 in.
Thickness: 0.312 in. |
2.3 lb/ft2 |
PHYSICAL RATINGS
| Product |
Standard |
Rating |
| HardiePanel® Vertical Siding smooth and textured (HZ5 and HZ10); HardieSoffit® smooth and textured, vented and non-vented (HZ5 and HZ10); Prevail® Soffit, smooth and textured, vented and non-vented; CemPanel® Vertical Siding, and Prevail® Panel |
ASTM C1186 |
Meets Grade II, Type A |
| BS EN 12467 |
Meets Category A, Class 2, Level I |
| ISO 8336 |
Meets Category A, Class 2, Level I |
FIRE RATINGS
| Product |
Standard |
Rating |
Design Listing Number |
| HardiePanel® Vertical Siding, CemPanel® Vertical Siding, Prevail® Panel Siding, HardieSoffit® Panel, and Prevail® Soffit Panel. |
ASTM E136 |
Non-combustible |
N/A |
| ASTM E84 |
Flame Spread Index: 0
Smoke Developed Index: 0 |
N/A |
| CAN/ULC S102 |
Flame Spread Index: 0
Smoke Developed Index: 0 |
N/A |
| HardiePanel® Vertical Siding, CemPanel® Vertical Siding, and Prevail® Panel Siding |
ASTM E119
CAN/ULC S101 |
1 Hour |
JH/FCS 60-02 |
| JH/FCS 60-03 |
| JH/FCS 60-01 |
| JH/FCS 60-04 |
2 Hours
|
JH/FCS 120-01 |
| JH/FCS 120-02 |
| HardiePanel® Vertical Siding |
CA/ULC S114 |
Non-combustible |
NA |
| HardieSoffit® Panel (Non-vented only) |
NFPA 286 |
Meets the requirements |
NA
See assembly details below |
| Prevail® Soffit Panel (Non-vented only) |
NFPA 286 |
Meets the requirements |
NA
See assembly details below |
HardieSoffit® Panels and Prevail® Soffit Panels
meet the requirements of NFPA 286 when installed in the following configuration:
· Steel Studs: 20 GA (0.0359 in.) galvanized steel suds, spaced 24 in. on center
· Substrate Sheathing: 0.5 in. thick DensGlass® Gold fastened at 12 in. intervals around the perimeter and in the field.
· Insulation: 2.5 in. thick Dow STYROFOAM™ Extruded Polystyrene insulation fastened through the DensGlass into the studs at 12 in. intervals along the perimeter and in the field or 2.5 in. thick 2-2.2 pcf SPRAYTITE 178 BASF spray polyurethane foam insulation.
· Exposed Side: Any 0.25 in. thick HardieSoffit® or Prevail® Soffit
Panel
· Steel C-channel framing forms the frame at 24 in. on center. In the case that SPRAYTITE insulation is used, 2.5 in. steel Z-grits are attached horizontally across the width of the wall every 24 in. of height.
ASTM E331 RATINGS
| System No. |
#1 |
Results:
Details: |
HardiePanel® Vertical Siding meets the requirements of ASTM E331 when subjected to a pressure of 137 Pa and water spray rate of 5.0 US gal/ft2h for 15 minutes
- Frame: SPF grade 2, nominal 2 in. x 4 in. studs spaced 24 in. on center. Double studs used at vertical panel joints with nominal 2 in. x 4 in. blocking at horizontal panel joints. Framing members fastened using 2-1/2 in. coil nails spaced 6 in. on the perimeter and 12 in. in-field
- Panel Fastening: 2-1/2 in. coil nails used to fasten HardiePanel® 6 in. on the perimeter and 12 in. in field; fasteners were kept 2 in. from each corner and 3/8 in. from the edges.
- Weather Barrier: A single layer of a Listed weather resistive barrier fastened to the sheathing using 1 in. crown staples spaced 12 in. on center with a 6 in. overlap at the horizontal center of the panel
- Joint Treatment: Two different vertical joint details; one joint using an extruded aluminum ½ in. Fry Reglet reveal, and the other joint using a folded steel U-channel reveal adhered with LePage® PL Premium adhesive and three No. 8 x ¾ in. self tapping screws sealed with silicone
- Flashing: Aluminum T-flashing strip at horizontal panel joints
|
FLORIDA PRODUCT APPROVAL
| Report No. |
Product Covered |
| FL No. 13223 |
Cempanel Siding
HardiePanel Siding
Prevail Panel Siding |
| FL No. 13265 |
HardieSoffit Panels
HardieSoffit VentedPlus Panels |