Intertek Directory of Building Products

James Hardie 7/16" Panel and Lap Sidings Company: James Hardie Building Products, Inc.

James Hardie Reveal® and Pressed Reveal® are fiber-cement panel sidings.
James Hardie Hardie® Plank VL smooth and textured are fiber-cement lap sidings which includes HardiePlank® Woodgrain VL and HardiePlank® Smooth VL.
 
Product Dimensions Weight
Reveal® Width: 48 in.
Length: 96 in.
Thickness: 7/16 in.
3.1 lbs/ft2
Pressed Reveal® Width: 48 in.
Length: 96 in.
Thickness: 7/16 in.
4.3 lbs/ft2
James Hardie Hardie® Plank VL Width: 8.42 in.
Length: 144 in.
Thickness: 7/16 in.
2.79 lbs/ft2
 
PHYSICAL RATINGS
 
Product Standard Rating
Reveal® and Pressed Reveal® Panel Sidings; Hardie® Plank VL Lap Sidings ASTM C1186 Meets Grade II, Type A
BS EN 12467 Meets Category A, Class 2, Level I
ISO 8336 Meets Category A, Class 2, Level I
 
FIRE RATINGS
 
Product Standard Rating Design Listing Number
Reveal® and Pressed Reveal® Panel Sidings ASTM E84 Flame Spread Index: 0
Smoke Developed Index: 0
N/A
CAN/ULC S102 Flame Spread Rating: 0
Smoke Developed Classification: 5
N/A
Hardie® Plank VL Lap Sidings ASTM E84 Flame Spread Index: 0
Smoke Developed Index: 0
N/A
CAN/ULC S102 Flame Spread Rating: 0
Smoke Developed Classification: 0
N/A
Reveal® and Pressed Reveal® Panel Sidings; Hardie® Plank VL Lap Sidings ASTM E136 Non-combustible N/A
CAN/ULC S114 Non-combustible N/A
ASTM E119
CAN/ULC S101
1 Hour JH/FCS 60-01
JH/FCS 60-02
JH/FCS 60-03
JH/FCS 60-04
2 Hours  JH/FCS 120-01
JH/FCS 120-02
 
STRUCTURAL RATINGS

Structural ratings for Reveal® and Pressed Reveal® Panel Sidings per ASTM E330:
System No. #1
Results:
Details:
Ultimate Load: 127.4 psf 
  • Framing: 20 GA Steel (nominal 2x4)
  • Stud spacing: 16 in. on center
  • Fastener Type: #8 x 1-5/8 in. long buglehead self-tapping screw, 0.397 in. head diameter, 0.121 in. shank diameter
  • Fastener spacing: 3 fasteners at 16" o.c
System No. #2
Results:
Details:
Ultimate Load: 99.5 psf 
  • Framing: 20 GA Steel (nominal 2x4)
  • Stud spacing: 24 in. on center
  • Fastener Type: #8 x 1-5/8 in. long buglehead self-tapping screw, 0.397 in. head diameter, 0.121 in. shank diameter
  • Fastener spacing: 3 fasteners at 16" o.c
System No. #3
Results:
Details:
Ultimate Load: 128.5 psf 
  • Framing: 20 GA Steel (nominal 2x4)
  • Stud spacing: 16 in. on center
  • Fastener Type: #8 x 1-5/8 in. long buglehead self-tapping screw, 0.397 in. head diameter, 0.121 in. shank diameter
  • Fastener spacing: 4 fasteners at 12" o.c 
System No. #4
Results:
Details:
Ultimate Load: 111.3 psf 
  • Framing: Wood nominal 2x4 SPF #2+BTR
  • Furring: Treated ¾ in. x 4 in.
  • Stud spacing: 16 in. on center
  • Fastener Type: #8 x 1-5/8 in. long buglehead self-tapping screw, 0.397 in. head diameter, 0.121 in. shank diameter
  • Fastener spacing: 3 fasteners at 16" o.c
System No. #5
Results:
Details:
Ultimate Load: 110.1 psf 
  • Framing: Wood nominal 2x4 SPF #2+BTR
  • Furring: Treated ¾ in. x 4 in.
  • Stud spacing: 24 in. on center
  • Fastener Type: #8 x 1-5/8 in. long buglehead self-tapping screw, 0.397 in. head diameter, 0.121 in. shank diameter
  • Fastener spacing: 3 fasteners at 16" o.c
System No. #6
Results:
Details:
Ultimate Load: 134.4 psf 
  • Framing: Wood nominal 2x4 SPF #2+BTR
  • Furring: Treated ¾ in. x 4 in.
  • Stud spacing: 16 in. on center
  • Fastener Type: #8 x 1-5/8 in. long buglehead self-tapping screw, 0.397 in. head diameter, 0.121 in. shank diameter
  • Fastener spacing: 4 fasteners at 12" o.c
System No. #7
Results:
Details:
Ultimate Load: 150 psf 
  • Framing: 20 GA Steel (nominal 2x4)
  • Stud spacing: 24 in. on center
  • Fastener Type: #8 x 1-1/2 in. long panhead screw, 0.476 in. head diameter, 0.132 in. shank diameter
  • Fastener spacing: 4 fasteners at 12" o.c
System No. #8
Results:
Details:
Ultimate Load: 168.9 psf 
  • Framing: 20 GA Steel (nominal 2x4)
  • Stud spacing: 16 in. on center
  • Fastener Type: #10-12 x 1.2 in. long, 0.472 in. head dia. button head screw
  • Fastener spacing: 3 fasteners at 16" o.c
System No. #9
Results:
Details:
Ultimate Load: 207.6 psf 
  • Framing: 20 GA Steel (nominal 2x4)
  • Stud spacing: 16 in. on center
  • Fastener Type: #10-12 x 1.2 in. long, 0.472 in. head dia. button head screw
  • Fastener spacing: 4 fasteners at 12" o.c 
System No. #10
Results:
Details:
Ultimate Load: 172.2 psf 
  • Framing: Wood nominal 2x4 SPF #2+BTR
  • Furring: treated ¾ in. x 4 in.
  • Stud spacing: 24 in. on center
  • Fastener Type: #8 x 1-1/2 in. long panhead screw, 0.476 in. head diameter, 0.132 in. shank diameter
  • Fastener spacing: 4 fasteners at 12" o.c
System No. #11
Results:
Details:
Ultimate Load: 127.6 psf 
  • Framing: Wood nominal 2x4 SPF #2+BTR
  • Furring: 3/4 in. x 1-1/2 in. 6 ply plywood
  • Stud spacing: 16 in. on center
  • Fastener Type: #10-12 x 1.2 in. long, 0.472 in. head dia. button head screw
  • Fastener spacing: 3 fasteners at 16" o.c
System No. #12
Results:
Details:
Ultimate Load: 206.2 psf 
  • Framing: Wood nominal 2x4 SPF #2+BTR
  • Furring: 3/4 in. x 1-1/2 in. 6 ply plywood
  • Stud spacing: 16 in. on center
  • Fastener Type: #10-12 x 1.2 in. long, 0.472 in. head dia. button head screw
  • Fastener spacing: 4 fasteners at 12" o.c 
System No. #13
Results:
Details:
Ultimate Load: 137.1 psf 
  • Framing: Wood nominal 2x4 SPF #2+BTR
  • Furring: 3/4 in. x 1-1/2 in. 6 ply plywood
  • Stud spacing: 16 in. on center
  • Fastener Type: #20 Torx Head Svrew (SFS Intec TW-S-D12- 4.8 x 38)
  • Fastener spacing: 2 fasteners at 24" o.c
System No. #14
Results:
Details:
Ultimate Load: 137.1 psf 
  • Framing: Wood nominal 2x4 SPF #2+BTR
  • Furring: 3/4 in. x 1-1/2 in. 6 ply plywood
  • Stud spacing: 16 in. on center
  • Fastener Type: #20 Torx Head Svrew (SFS Intec TW-S-D12- 4.8 x 38)
  • Fastener spacing: 2 fasteners at 24" o.c 
 
 
Reveal® and Pressed Reveal® Panel Sidings comply with the requirements of AAMA 509 when tested with the following installation details:
System No. #1
Results:
Details:
Meets the requirements of AAMA 509
  • Framing: SPF wood framing, nominal 2 in. x 6 in.
  • Furring: 3/4 in. thick x 4 in. wide pressure treated plywood
  • Weather Barrier: One layer of Tyvek ® HomeWrap ® installed over framing, stapled at 24 in. on center
  • Fastener Type: Countersunk #8 x 1-5/8 in. long buglehead screws
  • Fastener Spacing: 16 in. at o.c
 
FLORIDA PRODUCT INFORMATION
Product Evaluated  FL No.
Reveal® and Pressed Reveal® Panel Sidings 19901
Listing Report Return to Search
Attributes
CriteriaCAN / ULC S101 (2007)
CriteriaCAN / ULC S114 (2005)
CriteriaCAN / ULC S102 (2010)
CriteriaAAMA 509 (2009)
CriteriaASTM E136 (2012)
CriteriaCAN / ULC S101 (2014)
CriteriaASTM E84 (2015)
CriteriaASTM E119 (2015)
CriteriaASTM E330 (2014) (R2021)
CriteriaASTM C1186-08 (R2012)
CriteriaISO 8336 (2009)
CriteriaEN 12467:2012 +A1
CriteriaASTM E84 (2016)
CriteriaASTM E136 (2016) Ed.16a
CriteriaASTM E119 (2016)
CriteriaASTM C1186 (2008) (R2016)
CriteriaISO 8336:2017 Ed.3
CriteriaASTM E84 (2018b)
CriteriaASTM E136 (2019)
CriteriaASTM E119 (2018b)
CriteriaASTM C1186 (2022) E1
CSI Code07 46 00 Siding
Listing SectionWALL ASSEMBLIES
Spec ID39761
Design Documents
Public Documents
No Results