Intertek Directory of Building Products

James Hardie 7/16" Panel and Lap Sidings Company: James Hardie Building Products, Inc.

James Hardie Reveal® and Pressed Reveal® are fiber-cement panel sidings.
James Hardie Hardie® Plank VL smooth and textured are fiber-cement lap sidings which includes HardiePlank® Woodgrain VL and HardiePlank® Smooth VL.
 
Product Dimensions Weight
Reveal® Width: 48 in.
Length: 96 in.
Thickness: 7/16 in.
3.1 lbs/ft2
Pressed Reveal® Width: 48 in.
Length: 96 in.
Thickness: 7/16 in.
4.3 lbs/ft2
James Hardie Hardie® Plank VL Width: 8.42 in.
Length: 144 in.
Thickness: 7/16 in.
2.79 lbs/ft2
 
PHYSICAL RATINGS
 
Product Standard Rating
Reveal® and Pressed Reveal® Panel Sidings; Hardie® Plank VL Lap Sidings ASTM C1186 Meets Grade II, Type A
BS EN 12467 Meets Category A, Class 2, Level I
ISO 8336 Meets Category A, Class 2, Level I
 
FIRE RATINGS
 
Product Standard Rating Design Listing Number
Reveal® and Pressed Reveal® Panel Sidings ASTM E84 Flame Spread Index: 0
Smoke Developed Index: 0
N/A
CAN/ULC S102 Flame Spread Rating: 0
Smoke Developed Classification: 5
N/A
Hardie® Plank VL Lap Sidings ASTM E84 Flame Spread Index: 0
Smoke Developed Index: 0
N/A
CAN/ULC S102 Flame Spread Rating: 0
Smoke Developed Classification: 0
N/A
Reveal® and Pressed Reveal® Panel Sidings; Hardie® Plank VL Lap Sidings ASTM E136 Non-combustible N/A
CAN/ULC S114 Non-combustible N/A
ASTM E119
CAN/ULC S101
1 Hour JH/FCS 60-01
JH/FCS 60-02
JH/FCS 60-03
JH/FCS 60-04
2 Hours  JH/FCS 120-01
JH/FCS 120-02
 
STRUCTURAL RATINGS

Structural ratings for Reveal® and Pressed Reveal® Panel Sidings per ASTM E330:
System No. #1
Results:
Details:
Ultimate Load: 127.4 psf 
  • Framing: 20 GA Steel (nominal 2x4)
  • Stud spacing: 16 in. on center
  • Fastener Type: #8 x 1-5/8 in. long buglehead self-tapping screw, 0.397 in. head diameter, 0.121 in. shank diameter
  • Fastener spacing: 3 fasteners at 16" o.c
System No. #2
Results:
Details:
Ultimate Load: 99.5 psf 
  • Framing: 20 GA Steel (nominal 2x4)
  • Stud spacing: 24 in. on center
  • Fastener Type: #8 x 1-5/8 in. long buglehead self-tapping screw, 0.397 in. head diameter, 0.121 in. shank diameter
  • Fastener spacing: 3 fasteners at 16" o.c
System No. #3
Results:
Details:
Ultimate Load: 128.5 psf 
  • Framing: 20 GA Steel (nominal 2x4)
  • Stud spacing: 16 in. on center
  • Fastener Type: #8 x 1-5/8 in. long buglehead self-tapping screw, 0.397 in. head diameter, 0.121 in. shank diameter
  • Fastener spacing: 4 fasteners at 12" o.c 
System No. #4
Results:
Details:
Ultimate Load: 111.3 psf 
  • Framing: Wood nominal 2x4 SPF #2+BTR
  • Furring: Treated ¾ in. x 4 in.
  • Stud spacing: 16 in. on center
  • Fastener Type: #8 x 1-5/8 in. long buglehead self-tapping screw, 0.397 in. head diameter, 0.121 in. shank diameter
  • Fastener spacing: 3 fasteners at 16" o.c
System No. #5
Results:
Details:
Ultimate Load: 110.1 psf 
  • Framing: Wood nominal 2x4 SPF #2+BTR
  • Furring: Treated ¾ in. x 4 in.
  • Stud spacing: 24 in. on center
  • Fastener Type: #8 x 1-5/8 in. long buglehead self-tapping screw, 0.397 in. head diameter, 0.121 in. shank diameter
  • Fastener spacing: 3 fasteners at 16" o.c
System No. #6
Results:
Details:
Ultimate Load: 134.4 psf 
  • Framing: Wood nominal 2x4 SPF #2+BTR
  • Furring: Treated ¾ in. x 4 in.
  • Stud spacing: 16 in. on center
  • Fastener Type: #8 x 1-5/8 in. long buglehead self-tapping screw, 0.397 in. head diameter, 0.121 in. shank diameter
  • Fastener spacing: 4 fasteners at 12" o.c
System No. #7
Results:
Details:
Ultimate Load: 150 psf 
  • Framing: 20 GA Steel (nominal 2x4)
  • Stud spacing: 24 in. on center
  • Fastener Type: #8 x 1-1/2 in. long panhead screw, 0.476 in. head diameter, 0.132 in. shank diameter
  • Fastener spacing: 4 fasteners at 12" o.c
System No. #8
Results:
Details:
Ultimate Load: 168.9 psf 
  • Framing: 20 GA Steel (nominal 2x4)
  • Stud spacing: 16 in. on center
  • Fastener Type: #10-12 x 1.2 in. long, 0.472 in. head dia. button head screw
  • Fastener spacing: 3 fasteners at 16" o.c
System No. #9
Results:
Details:
Ultimate Load: 207.6 psf 
  • Framing: 20 GA Steel (nominal 2x4)
  • Stud spacing: 16 in. on center
  • Fastener Type: #10-12 x 1.2 in. long, 0.472 in. head dia. button head screw
  • Fastener spacing: 4 fasteners at 12" o.c 
System No. #10
Results:
Details:
Ultimate Load: 172.2 psf 
  • Framing: Wood nominal 2x4 SPF #2+BTR
  • Furring: treated ¾ in. x 4 in.
  • Stud spacing: 24 in. on center
  • Fastener Type: #8 x 1-1/2 in. long panhead screw, 0.476 in. head diameter, 0.132 in. shank diameter
  • Fastener spacing: 4 fasteners at 12" o.c
System No. #11
Results:
Details:
Ultimate Load: 127.6 psf 
  • Framing: Wood nominal 2x4 SPF #2+BTR
  • Furring: 3/4 in. x 1-1/2 in. 6 ply plywood
  • Stud spacing: 16 in. on center
  • Fastener Type: #10-12 x 1.2 in. long, 0.472 in. head dia. button head screw
  • Fastener spacing: 3 fasteners at 16" o.c
System No. #12
Results:
Details:
Ultimate Load: 206.2 psf 
  • Framing: Wood nominal 2x4 SPF #2+BTR
  • Furring: 3/4 in. x 1-1/2 in. 6 ply plywood
  • Stud spacing: 16 in. on center
  • Fastener Type: #10-12 x 1.2 in. long, 0.472 in. head dia. button head screw
  • Fastener spacing: 4 fasteners at 12" o.c 
System No. #13
Results:
Details:
Ultimate Load: 137.1 psf 
  • Framing: Wood nominal 2x4 SPF #2+BTR
  • Furring: 3/4 in. x 1-1/2 in. 6 ply plywood
  • Stud spacing: 16 in. on center
  • Fastener Type: #20 Torx Head Svrew (SFS Intec TW-S-D12- 4.8 x 38)
  • Fastener spacing: 2 fasteners at 24" o.c
System No. #14
Results:
Details:
Ultimate Load: 137.1 psf 
  • Framing: Wood nominal 2x4 SPF #2+BTR
  • Furring: 3/4 in. x 1-1/2 in. 6 ply plywood
  • Stud spacing: 16 in. on center
  • Fastener Type: #20 Torx Head Svrew (SFS Intec TW-S-D12- 4.8 x 38)
  • Fastener spacing: 2 fasteners at 24" o.c 
 
 
Reveal® and Pressed Reveal® Panel Sidings comply with the requirements of AAMA 509 when tested with the following installation details:
System No. #1
Results:
Details:
Meets the requirements of AAMA 509
  • Framing: SPF wood framing, nominal 2 in. x 6 in.
  • Furring: 3/4 in. thick x 4 in. wide pressure treated plywood
  • Weather Barrier: One layer of Tyvek ® HomeWrap ® installed over framing, stapled at 24 in. on center
  • Fastener Type: Countersunk #8 x 1-5/8 in. long buglehead screws
  • Fastener Spacing: 16 in. at o.c
 
FLORIDA PRODUCT INFORMATION
Product Evaluated  FL No.
Reveal® and Pressed Reveal® Panel Sidings 19901
Listing Report Return to Search
Attributes
CriteriaCAN / ULC S101 (2007)
CriteriaCAN / ULC S114 (2005)
CriteriaCAN / ULC S102 (2010)
CriteriaAAMA 509 (2009)
CriteriaASTM E136 (2012)
CriteriaCAN / ULC S101 (2014)
CriteriaASTM E136 (2019)
CriteriaASTM E119 (2018b)
CriteriaASTM C1186 (2022) E1
CriteriaASTM E84 (2016)
CriteriaASTM E136 (2016) Ed.16a
CriteriaASTM E119 (2016)
CriteriaASTM C1186 (2008) (R2016)
CriteriaISO 8336:2017 Ed.3
CriteriaASTM E84 (2018b)
CriteriaASTM E84 (2015)
CriteriaASTM E119 (2015)
CriteriaASTM E330 (2014) (R2021)
CriteriaASTM C1186-08 (R2012)
CriteriaISO 8336 (2009)
CriteriaEN 12467:2012 +A1
CSI Code07 46 00 Siding
Listing SectionWALL ASSEMBLIES
Spec ID39761
Design Documents
Public Documents
No Results