Intertek Directory of Building Products

SAFTI FIRST GPX/SuperLite II XLM 60 Fire Rated Wall Assembly Company: SAFTI FIRST

PRODUCT DESCRIPTION

SAFTI FIRST GPX/SuperLite II XLM 60 or Superlite II XLM-60 C Fire Rated Wall Assembly is composed of a multi-layered glass panel laminated together by a fire resistive intumescent interlayer.  Glass panels are nominally 1 inch (23mm, 25mm or 27mm) thick.  The GPX Framing system main components include tubular steel, gypsum boards, composite framing, aluminum snap on covers, and Insulation. 

RATINGS
SF/GG 60-02
ASTM E119 - 1 hrs
GPX / SuperLite II-XLM 60  
Max Individual Panel Dimensions (Clear View)
Maximum Allowable Panel Area 3855 sq. in.
Maximum Allowable Panel Width 87-5/8 in.
Maximum Allowable Panel Height 87- 5/8 in.
 
ASTM E119 - 1 hrs
GPX / SuperLite II-XLM- 60 C
Max Individual Panel Dimensions (Clear View)
Maximum Allowable Panel Area 3355 sq. in.
Maximum Allowable Panel Width 95-1/4 in. (2419mm)
Maximum Allowable Panel Height 95-1/4 in. (2419mm)
Minimum Stop Height  5/8" (16 mm)  1/2" bite
Minimum Nominal Thickness 0.90in. (23mm)

 
Listing Report Return to Search
Attributes
CriteriaUL 263 (2011)
CriteriaCAN / ULC S101 (2014)
CriteriaASTM E119 (2015)
CSI Code08 80 00 Glazing
Listing SectionGLAZING/GLASS
Spec ID41816